Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Supply Voltage | Vcc | 15 | - | 30 | V | Operating voltage range |
Control Voltage | Vc | 0 | - | 12 | V | Input control voltage |
Output Current | Iout | 0.5 | - | 1.5 | A | Maximum output current |
Trigger Sensitivity | Vt | 0.6 | 1.2 | 2.4 | V | Threshold voltage for triggering |
Non-triggering Voltage | Vnt | 0.3 | 0.6 | 1.2 | V | Voltage below which the trigger is reset |
Maximum Power Dissipation | Pd | - | - | 1000 | mW | Maximum power dissipation |
Operating Temperature | Toper | -40 | - | 125 | °C | Operating temperature range |
Storage Temperature | Tstg | -55 | - | 150 | °C | Storage temperature range |
Instructions for Using TCA785:
Power Supply:
- Ensure the supply voltage (Vcc) is within the range of 15V to 30V.
- Connect the positive terminal of the power supply to Vcc and the negative terminal to GND.
Control Voltage:
- Apply the control voltage (Vc) to the control input pin. The control voltage should be between 0V and 12V.
- The control voltage determines the firing angle of the thyristor or triac.
Output Current:
- The TCA785 can handle an output current (Iout) ranging from 0.5A to 1.5A.
- Ensure that the load connected to the output does not exceed this current limit.
Triggering:
- The device triggers when the control voltage (Vc) exceeds the trigger sensitivity (Vt), typically between 0.6V and 2.4V.
- Once triggered, the device remains on until the control voltage drops below the non-triggering voltage (Vnt), typically between 0.3V and 1.2V.
Power Dissipation:
- The maximum power dissipation (Pd) is 1000mW. Ensure adequate heat sinking if operating near this limit.
Temperature:
- The operating temperature range (Toper) is from -40°C to 125°C.
- The storage temperature range (Tstg) is from -55°C to 150°C.
Handling and Storage:
- Handle the TCA785 with care to avoid static damage.
- Store the device in a dry environment within the specified storage temperature range.
Circuit Design:
- Use appropriate decoupling capacitors near the power supply pins to filter out noise.
- Ensure proper grounding and shielding to minimize electromagnetic interference.
Safety:
- Always follow safety guidelines when working with high voltages and currents.
- Use protective equipment such as gloves and goggles when handling the device.
By following these instructions, you can ensure reliable operation of the TCA785 in your circuit.