TCA785

TCA785

Category: IC Chips

Specifications
SKU
12533323
Details

BUY TCA785 https://www.utsource.net/itm/p/12533323.html

Parameter Symbol Min Typ Max Unit Description
Supply Voltage Vcc 15 - 30 V Operating voltage range
Control Voltage Vc 0 - 12 V Input control voltage
Output Current Iout 0.5 - 1.5 A Maximum output current
Trigger Sensitivity Vt 0.6 1.2 2.4 V Threshold voltage for triggering
Non-triggering Voltage Vnt 0.3 0.6 1.2 V Voltage below which the trigger is reset
Maximum Power Dissipation Pd - - 1000 mW Maximum power dissipation
Operating Temperature Toper -40 - 125 °C Operating temperature range
Storage Temperature Tstg -55 - 150 °C Storage temperature range

Instructions for Using TCA785:

  1. Power Supply:

    • Ensure the supply voltage (Vcc) is within the range of 15V to 30V.
    • Connect the positive terminal of the power supply to Vcc and the negative terminal to GND.
  2. Control Voltage:

    • Apply the control voltage (Vc) to the control input pin. The control voltage should be between 0V and 12V.
    • The control voltage determines the firing angle of the thyristor or triac.
  3. Output Current:

    • The TCA785 can handle an output current (Iout) ranging from 0.5A to 1.5A.
    • Ensure that the load connected to the output does not exceed this current limit.
  4. Triggering:

    • The device triggers when the control voltage (Vc) exceeds the trigger sensitivity (Vt), typically between 0.6V and 2.4V.
    • Once triggered, the device remains on until the control voltage drops below the non-triggering voltage (Vnt), typically between 0.3V and 1.2V.
  5. Power Dissipation:

    • The maximum power dissipation (Pd) is 1000mW. Ensure adequate heat sinking if operating near this limit.
  6. Temperature:

    • The operating temperature range (Toper) is from -40°C to 125°C.
    • The storage temperature range (Tstg) is from -55°C to 150°C.
  7. Handling and Storage:

    • Handle the TCA785 with care to avoid static damage.
    • Store the device in a dry environment within the specified storage temperature range.
  8. Circuit Design:

    • Use appropriate decoupling capacitors near the power supply pins to filter out noise.
    • Ensure proper grounding and shielding to minimize electromagnetic interference.
  9. Safety:

    • Always follow safety guidelines when working with high voltages and currents.
    • Use protective equipment such as gloves and goggles when handling the device.

By following these instructions, you can ensure reliable operation of the TCA785 in your circuit.

(For reference only)

View more about TCA785 on main site