Parameter Symbol Min Typical Max Unit Notes
Supply Voltage Vcc 1.6 - 5.5 V
Output Current Iout - 200 250 mA
Operating Temperature Topr -40 - 85 °C
Storage Temperature Tstg -65 - 150 °C
Quiescent Current Iq - 1.5 2.5 μA
Dropout Voltage Vdo - 200 300 mV @ Iout = 200mA, Vcc = 3.3V
Load Regulation ΔVL - 0.5 1.0 % 0mA to 200mA
Line Regulation ΔVL - 0.1 0.2 %/V Vcc = 2.7V to 5.5V
PSRR (Power Supply Rejection Ratio) PSRR - 60 70 dB @ 1kHz, Vcc = 3.3V
Transient Response Time Tr - 30 50 μs Step load from 0mA to 200mA

Instructions for Use:

  1. Supply Voltage (Vcc):

    • Ensure the supply voltage is within the range of 1.6V to 5.5V.
    • Avoid exceeding the maximum supply voltage to prevent damage.
  2. Output Current (Iout):

    • The device can provide up to 250mA of output current, with a typical current of 200mA.
    • Ensure the load does not exceed the maximum output current to avoid overheating.
  3. Operating Temperature (Topr):

    • The operating temperature range is from -40°C to 85°C.
    • Ensure the device operates within this temperature range to maintain reliability.
  4. Storage Temperature (Tstg):

    • The storage temperature range is from -65°C to 150°C.
    • Store the device in a suitable environment to prevent degradation.
  5. Quiescent Current (Iq):

    • The quiescent current is typically 1.5μA and should not exceed 2.5μA.
    • This low quiescent current makes the device suitable for battery-powered applications.
  6. Dropout Voltage (Vdo):

    • The dropout voltage is typically 200mV and should not exceed 300mV at an output current of 200mA and a supply voltage of 3.3V.
    • Ensure the input voltage is sufficiently higher than the output voltage to maintain regulation.
  7. Load Regulation (ΔVL):

    • The load regulation is typically 0.5% and should not exceed 1.0%.
    • This indicates the stability of the output voltage under varying load conditions.
  8. Line Regulation (ΔVL):

    • The line regulation is typically 0.1%/V and should not exceed 0.2%/V.
    • This indicates the stability of the output voltage under varying input voltage conditions.
  9. PSRR (Power Supply Rejection Ratio):

    • The PSRR is typically 60dB and should not exceed 70dB at 1kHz and a supply voltage of 3.3V.
    • This parameter measures the ability of the device to reject ripple on the input supply.
  10. Transient Response Time (Tr):

    • The transient response time is typically 30μs and should not exceed 50μs for a step load from 0mA to 200mA.
    • This indicates the speed at which the device can respond to sudden changes in load.

Additional Notes:

  • Always refer to the datasheet for detailed specifications and application notes.
  • Use appropriate decoupling capacitors to ensure stable operation.
  • Ensure proper heat dissipation if the device is operating near its maximum current or temperature limits.