Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | V_IN | 10 | 75 | V | Operating input voltage range | |
Switching Frequency | f_SW | 65 | 300 | kHz | Adjustable switching frequency | |
Output Power | P_OUT | 400 | W | Maximum output power | ||
Efficiency | η | 92 | % | Typical efficiency at full load | ||
Quiescent Current | I_Q | 0.3 | mA | Quiescent current | ||
Protection Features | Overcurrent, overvoltage, undervoltage lockout, thermal shutdown |
Instructions for UCC28600DR
Power Supply Connection:
- Connect the input power supply to the designated pins ensuring it is within the operating voltage range of 10V to 75V.
Setting the Switching Frequency:
- Adjust the external resistor connected to the RT/CT pin to set the desired switching frequency between 65kHz and 300kHz.
Output Configuration:
- Configure the output stage according to the maximum output power requirement (up to 400W).
Efficiency Optimization:
- For optimal efficiency, operate the device under conditions that allow it to achieve its typical efficiency of 92%.
Protection Circuits:
- Ensure all protection features (overcurrent, overvoltage, undervoltage lockout, and thermal shutdown) are properly configured and tested.
Quiescent Current Consideration:
- Be mindful of the quiescent current of 0.3mA when designing low-power applications.
Thermal Management:
- Implement adequate heat dissipation methods to prevent overheating and ensure reliable operation.
Refer to Datasheet:
- Always refer to the detailed datasheet for more specific parameters and application notes.