Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Supply Voltage | VCC | 10 | - | 20 | V | |
Under Voltage Lockout | UVLO | 8.5 | - | 10 | V | Disable |
Input High Level Voltage | VIH | 2 | - | 15 | V | |
Input Low Level Voltage | VIL | 0 | - | 0.8 | V | |
Output Source Current | IOS | - | 140 | - | mA | @VCC = 15V |
Output Sink Current | IOL | - | 190 | - | mA | @VCC = 15V |
Propagation Delay Time | tpd | - | 75 | - | ns | |
Power Dissipation | PD | - | - | 670 | mW | Ta = 25°C |
Operating Temperature | TJ | -40 | - | 125 | °C |
Instructions for IR2117STRPBF
Supply Voltage (VCC):
- Ensure the supply voltage is within the range of 10V to 20V.
Under Voltage Lockout (UVLO):
- The device will disable when the supply voltage drops below 8.5V, re-enabling above 10V.
Input Voltage Levels:
- For reliable operation, input high voltage should be at least 2V and can go up to 15V.
- Input low voltage should not exceed 0.8V.
Output Current:
- The output source current should not exceed 140mA.
- The output sink current should not exceed 190mA.
Propagation Delay Time:
- Expect a typical propagation delay time of 75ns.
Power Dissipation:
- Keep power dissipation below 670mW to ensure safe operation, especially at ambient temperatures of 25°C.
Operating Temperature:
- The device is designed to operate between -40°C and 125°C.
Handling Precautions:
- Follow standard ESD handling precautions to prevent damage to the component.
- Ensure proper heat sinking if operating near maximum power dissipation limits.
Application Notes:
- Refer to the manufacturer’s application notes for detailed guidelines on circuit design and troubleshooting.