Details
BUY AD588KQ https://www.utsource.net/itm/p/12535033.html
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Supply Voltage | Vcc | 4.5 | - | 18 | V | - |
Output Voltage Range | Vout | 0 | - | Vcc - 1.5 | V | - |
Reference Voltage | Vref | 4.995 | 5.000 | 5.005 | V | 25°C |
Initial Accuracy | ΔVref | -0.1 | 0 | +0.1 | % | 25°C |
Temperature Coefficient | Tc | -10 | 0 | +10 | ppm/°C | -40 to +85°C |
Line Regulation | ΔVref/ΔVcc | - | 10 | - | ppm/V | - |
Load Regulation | ΔVref/ΔIload | - | 1 | - | ppm/mA | - |
Long-Term Stability | ΔVref/Δt | - | 10 | - | ppm/1000h | 25°C |
Output Current | Iout | -10 | 0 | 10 | mA | - |
Operating Temperature Range | Toper | -40 | - | +85 | °C | - |
Instructions for Using AD588KQ:
Supply Voltage (Vcc):
- Ensure the supply voltage is within the range of 4.5V to 18V.
- Use a stable power source to avoid fluctuations that could affect the reference voltage.
Output Voltage Range (Vout):
- The output voltage can range from 0V to Vcc - 1.5V.
- Design your circuit to ensure the load does not exceed this range.
Reference Voltage (Vref):
- The reference voltage is nominally 5.000V at 25°C.
- The initial accuracy is ±0.1% at 25°C, so calibrate your system accordingly.
Temperature Coefficient (Tc):
- The temperature coefficient is ±10ppm/°C over the operating temperature range of -40°C to +85°C.
- Consider thermal management to minimize temperature variations if high precision is required.
Line Regulation (ΔVref/ΔVcc):
- The line regulation is 10ppm/V.
- Ensure the supply voltage is stable to maintain the reference voltage accuracy.
Load Regulation (ΔVref/ΔIload):
- The load regulation is 1ppm/mA.
- Keep the output current within the specified range to avoid significant changes in the reference voltage.
Long-Term Stability (ΔVref/Δt):
- The long-term stability is 10ppm/1000 hours at 25°C.
- Periodically recalibrate your system to account for any drift over time.
Output Current (Iout):
- The output current should be kept between -10mA and +10mA.
- Exceeding these limits can damage the device or reduce its performance.
Operating Temperature Range (Toper):
- The device operates reliably between -40°C and +85°C.
- Avoid operating the device outside this range to prevent damage or reduced performance.
Handling and Storage:
- Store the device in a dry, cool place to prevent moisture damage.
- Handle with care to avoid static discharge, which can damage sensitive components.
By following these instructions, you can ensure optimal performance and reliability of the AD588KQ precision voltage reference.
(For reference only)View more about AD588KQ on main site