Parameter Symbol Min Typ Max Unit Conditions
Supply Voltage Vcc 4.5 - 18 V -
Output Voltage Range Vout 0 - Vcc - 1.5 V -
Reference Voltage Vref 4.995 5.000 5.005 V 25°C
Initial Accuracy ΔVref -0.1 0 +0.1 % 25°C
Temperature Coefficient Tc -10 0 +10 ppm/°C -40 to +85°C
Line Regulation ΔVref/ΔVcc - 10 - ppm/V -
Load Regulation ΔVref/ΔIload - 1 - ppm/mA -
Long-Term Stability ΔVref/Δt - 10 - ppm/1000h 25°C
Output Current Iout -10 0 10 mA -
Operating Temperature Range Toper -40 - +85 °C -

Instructions for Using AD588KQ:

  1. Supply Voltage (Vcc):

    • Ensure the supply voltage is within the range of 4.5V to 18V.
    • Use a stable power source to avoid fluctuations that could affect the reference voltage.
  2. Output Voltage Range (Vout):

    • The output voltage can range from 0V to Vcc - 1.5V.
    • Design your circuit to ensure the load does not exceed this range.
  3. Reference Voltage (Vref):

    • The reference voltage is nominally 5.000V at 25°C.
    • The initial accuracy is ±0.1% at 25°C, so calibrate your system accordingly.
  4. Temperature Coefficient (Tc):

    • The temperature coefficient is ±10ppm/°C over the operating temperature range of -40°C to +85°C.
    • Consider thermal management to minimize temperature variations if high precision is required.
  5. Line Regulation (ΔVref/ΔVcc):

    • The line regulation is 10ppm/V.
    • Ensure the supply voltage is stable to maintain the reference voltage accuracy.
  6. Load Regulation (ΔVref/ΔIload):

    • The load regulation is 1ppm/mA.
    • Keep the output current within the specified range to avoid significant changes in the reference voltage.
  7. Long-Term Stability (ΔVref/Δt):

    • The long-term stability is 10ppm/1000 hours at 25°C.
    • Periodically recalibrate your system to account for any drift over time.
  8. Output Current (Iout):

    • The output current should be kept between -10mA and +10mA.
    • Exceeding these limits can damage the device or reduce its performance.
  9. Operating Temperature Range (Toper):

    • The device operates reliably between -40°C and +85°C.
    • Avoid operating the device outside this range to prevent damage or reduced performance.
  10. Handling and Storage:

    • Store the device in a dry, cool place to prevent moisture damage.
    • Handle with care to avoid static discharge, which can damage sensitive components.

By following these instructions, you can ensure optimal performance and reliability of the AD588KQ precision voltage reference.