Details

BUY INA126PA https://www.utsource.net/itm/p/12535086.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Continuous Operation 2.7 - 36 V
Input Voltage Range VIN Referenced to Ground 0 - VCC - 1.5 V
Output Voltage Range VOUT Referenced to Ground 0 - VCC - 1.5 V
Quiescent Current IQ VCC = 36V - 800 - 渭A
Input Bias Current IB VCC = 36V - 50 - nA
Input Offset Voltage VOS VCC = 36V - 200 - 渭V
Common-Mode Rejection Ratio CMRR VCC = 36V - 110 - dB
Power-Supply Rejection Ratio PSRR VCC = 36V - 100 - dB
Gain AV VCC = 36V - 5000 - V/V
Bandwidth fBW VCC = 36V, G = 1000 - 10 - kHz
Slew Rate SR VCC = 36V - 0.4 - V/渭s

Instructions for Using the INA126PA:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 2.7V to 36V.
    • Connect the positive supply to VCC and the negative supply to ground.
  2. Input Connection:

    • Connect the input signals to the non-inverting (IN+) and inverting (IN-) inputs.
    • Ensure the input voltage range is between 0V and VCC - 1.5V.
  3. Output Configuration:

    • The output voltage (VOUT) will be referenced to ground and should not exceed VCC - 1.5V.
    • Connect the output to the load or next stage of your circuit.
  4. Biasing and Offset:

    • The input bias current is typically 50nA, so ensure that the input sources can handle this current.
    • The input offset voltage is typically 200渭V, which may need to be considered in precision applications.
  5. Gain Setting:

    • The INA126PA has a fixed gain of 5000 V/V. No external resistors are required to set the gain.
  6. Common-Mode Rejection:

    • The INA126PA has a high common-mode rejection ratio (CMRR) of 110 dB, making it suitable for differential signal amplification.
  7. Power-Supply Rejection:

    • The power-supply rejection ratio (PSRR) is 100 dB, ensuring minimal noise from the power supply affects the output.
  8. Bandwidth and Slew Rate:

    • The bandwidth is 10 kHz at a gain of 1000, and the slew rate is 0.4 V/渭s. These parameters should be considered when designing the circuit to avoid distortion.
  9. Thermal Considerations:

    • Ensure proper heat dissipation if operating at higher supply voltages or in high ambient temperatures.
  10. Storage and Handling:

    • Store the INA126PA in a dry environment and handle with care to avoid damage from static electricity.
(For reference only)

View more about INA126PA on main site