Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Input Voltage | VIN | Operating | 2.7 | - | 40 | V |
Output Voltage | VOUT | Dropout | - | 1.3 | - | V |
Quiescent Current | IQ | VIN = 5V, IOUT=0 | - | 60 | - | μA |
Load Regulation | IOUT=1mA to 1A | - | 0.2 | - | % | |
Line Regulation | VIN=5V to 40V | - | 0.05 | - | % | |
Thermal Shutdown | TSD | Activation | - | 160 | - | °C |
Short-Circuit Current | ISC | VIN = 5V | - | 1.5 | - | A |
Instructions for MC33060AD
Input Voltage: Ensure the input voltage is within the specified range of 2.7V to 40V. Exceeding this range can damage the device.
Output Configuration: The dropout voltage is typically 1.3V. Design your circuit considering this to ensure stable output voltage.
Quiescent Current: At no load and an input voltage of 5V, the quiescent current is approximately 60μA. This should be factored into power consumption calculations.
Load Regulation: The change in output voltage due to load changes from 1mA to 1A is about 0.2%. This indicates good stability under varying loads.
Line Regulation: Changes in input voltage from 5V to 40V cause a typical line regulation of 0.05%, ensuring minimal output voltage fluctuation.
Thermal Protection: The device includes thermal shutdown protection which activates at approximately 160°C to prevent overheating damage.
Short-Circuit Protection: In case of a short circuit with an input voltage of 5V, the device limits the current to around 1.5A to protect against excessive current draw.
Installation and Handling: Follow standard handling practices for electronic components to avoid damage from electrostatic discharge (ESD). Ensure proper heat sinking if operating near maximum ratings.