Details
BUY 5M0380R https://www.utsource.net/itm/p/12535464.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Rated Voltage | VRMS | - | 500 | - | VAC | Maximum continuous RMS voltage |
| Peak Repetitive Voltage | VDRM | - | 700 | - | V | Maximum peak repetitive off-state voltage |
| Non-Repetitive Peak Surge Current | ISM | - | 3800 | - | A | Maximum non-repetitive surge current (8/20 μs) |
| Clamping Voltage at 100A | VC100 | - | 1050 | - | V | Clamping voltage at 100A peak current |
| Power Dissipation | PD | - | 400 | - | W | Maximum power dissipation |
| Thermal Resistance | Rth | - | 1.5 | - | °C/W | Junction to ambient thermal resistance |
| Operating Temperature | TJ | -40 | - | 150 | °C | Operating junction temperature range |
| Storage Temperature | TSTG | -65 | - | 150 | °C | Storage temperature range |
Instructions for Use:
Mounting:
- Ensure proper heat sinking to maintain the junction temperature within the specified operating range.
- Use appropriate mounting hardware to secure the device.
Voltage Handling:
- Do not exceed the rated voltage (500VAC) or peak repetitive voltage (700V).
- Ensure the clamping voltage (1050V at 100A) is considered when designing the circuit to avoid overvoltage conditions.
Current Handling:
- The device can handle a non-repetitive peak surge current of up to 3800A (8/20 μs waveform). Ensure that surge currents do not exceed this value.
- Continuous current should be managed to keep power dissipation below 400W.
Thermal Management:
- Monitor the junction temperature to ensure it remains within the -40°C to 150°C range.
- Use the thermal resistance (1.5°C/W) to calculate the required heat sink size.
Storage:
- Store the device in a dry, cool environment within the storage temperature range (-65°C to 150°C).
Safety Precautions:
- Handle with care to avoid mechanical damage.
- Follow all safety guidelines and standards for high-voltage and high-current applications.