Details

BUY DAC712P https://www.utsource.net/itm/p/12536038.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VDD Operating range 4.5 5.5 V
Output Voltage Range VOUT VDD = 5V 0 5 V
Differential Nonlinearity (DNL) DNL Full Scale, VDD = 5V -1 +1 LSB
Integral Nonlinearity (INL) INL Full Scale, VDD = 5V -1 +1 LSB
Settling Time tsettle 0V to Full Scale, VDD = 5V 6 μs
Power Dissipation PD All bits high, VDD = 5V 125 mW

Instructions for DAC712P

  1. Power Supply:

    • Connect the power supply pins (VDD and GND) ensuring the voltage is within the specified operating range of 4.5V to 5.5V.
  2. Digital Input:

    • Apply the digital input signal to the data input pins. Ensure the input levels are compatible with the logic levels of the device.
  3. Output Configuration:

    • The analog output (VOUT) will be proportional to the digital input code applied. The output can swing from 0V to nearly VDD depending on the input code.
  4. Initialization:

    • After applying power, initialize the DAC by setting the desired initial output level using the appropriate digital code.
  5. Updating Output:

    • To update the output voltage, provide a new digital code at the input. The DAC will settle to the new voltage within the specified settling time.
  6. Handling:

    • Be cautious of static electricity as it can damage the component. Use proper ESD precautions when handling.
  7. Storage:

    • Store in a dry environment away from direct sunlight and extreme temperatures to ensure longevity.
  8. Testing:

    • Regularly test the DAC under typical operating conditions to ensure it meets the performance specifications listed in the parameter table.
(For reference only)

View more about DAC712P on main site