Details

BUY CA3140T https://www.utsource.net/itm/p/12536111.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage Vcc Operating 3 30 V
Input Offset Voltage Vos Ta = +25掳C 2 10 mV
Input Bias Current Ib Ta = +25掳C 50 150 pA
Input Offset Current Ios Ta = +25掳C 5 15 pA
Differential Input Voltage Vid 卤14 V
Output Short-Circuit Continuous
Slew Rate SR 0.3 V/渭s
Unity Gain Bandwidth GBP 1 MHz
Large Signal Voltage Gain Avo RL=10k惟 100 dB
Quiescent Current IQ All outputs idle 80 400 渭A
Operating Temperature Temp -40 85 掳C

Instructions for CA3140T:

  1. Power Supply Connection:

    • Connect the supply voltage (Vcc) to pin 8 and ground (GND) to pin 4. Ensure the supply voltage is within the specified range of 3V to 30V.
  2. Input Connections:

    • Connect the non-inverting input (pin 3) and inverting input (pin 2) according to your circuit design. Be mindful of the differential input voltage limit of 卤14V.
  3. Output Configuration:

    • The output (pin 6) can be connected directly to a load or through additional components as needed. Ensure the output does not remain short-circuited continuously.
  4. Biasing and Compensation:

    • For stable operation, external compensation may be required depending on the application. Refer to specific application notes for detailed guidance.
  5. Temperature Considerations:

    • Ensure the device operates within the temperature range of -40掳C to +85掳C to avoid performance degradation or damage.
  6. Handling Precautions:

    • Handle the CA3140T with care to avoid static damage. Use proper ESD protection measures during assembly and handling.
  7. Testing:

    • After installation, test the circuit under typical operating conditions to ensure it meets the expected performance parameters. Adjust input signals and feedback networks as necessary.
(For reference only)

View more about CA3140T on main site