Parameter | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Forward Voltage | VF | - | 1.2 | 1.5 | V |
Peak Forward Current | IFP | - | 10 | 15 | A |
Repetitive Peak Reverse Voltage | VRRM | 500 | - | 700 | V |
Non-Repetitive Peak Reverse Voltage | VRRMS | 700 | - | 1000 | V |
Reverse Leakage Current | IR | - | 100 | 500 | μA |
Storage Temperature Range | Tstg | -40 | - | 100 | °C |
Operating Temperature Range | Topr | -40 | - | 100 | °C |
Isolation Voltage | VIORM | 2500 | - | 3750 | Vrms |
Turn-On Time | ton | - | 3 | 5 | μs |
Turn-Off Time | toff | - | 3 | 5 | μs |
Instructions for TLP641
Handling Precautions:
- Handle the device with care to avoid mechanical damage.
- Use appropriate ESD (Electrostatic Discharge) protection measures.
Mounting and Soldering:
- Ensure that the mounting surface is clean and free from contaminants.
- Use a soldering iron with a temperature setting of 260°C or less.
- Do not apply excessive heat or pressure during soldering.
Forward Current (IF):
- The peak forward current (IFP) should not exceed 15A to prevent damage to the device.
- For continuous operation, ensure that the forward current does not exceed the typical value of 10A.
Reverse Voltage (VR):
- The repetitive peak reverse voltage (VRRM) should not exceed 700V.
- For non-repetitive conditions, the peak reverse voltage (VRRMS) should not exceed 1000V.
Temperature Considerations:
- The storage temperature range (Tstg) is -40°C to 100°C.
- The operating temperature range (Topr) is also -40°C to 100°C.
- Ensure that the device operates within these temperature limits to avoid thermal stress.
Isolation Voltage:
- The isolation voltage (VIORM) should be maintained at 2500Vrms or higher to ensure proper insulation.
Timing Parameters:
- The turn-on time (ton) and turn-off time (toff) are typically 3μs, with a maximum of 5μs.
- Design the circuit to accommodate these timing parameters to ensure reliable operation.
Storage and Transportation:
- Store the device in a dry, cool place away from direct sunlight.
- Use static-shielded bags for transportation to protect against ESD.
Testing:
- Before installing the device in a circuit, perform initial testing to verify its functionality.
- Use a multimeter or appropriate test equipment to check the forward voltage (VF) and other parameters.
Compliance:
- Ensure that the device complies with all relevant safety and regulatory standards for your application.