Details
BUY TPS2812DR https://www.utsource.net/itm/p/12536583.html
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions/Notes |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 1.2 | - | 5.5 | V | Operating input voltage range |
| Output Voltage | VOUT | 0 | - | VIN | V | Controlled output voltage |
| Load Current | ILOAD | - | 300 | 600 | mA | Maximum load current |
| On-State Resistance | RON | - | 80 | 120 | mΩ | Typical on-state resistance at 25°C, 100mA |
| Off-State Leakage | ILEAK | - | 1 | 5 | μA | Maximum leakage current when off |
| Control Input Voltage | VEN | 0.7 | - | 1.8 | V | Threshold for enabling the device |
| Propagation Delay | tPD | - | 100 | 200 | ns | Time delay from control input to output change |
| Power Dissipation | PD | - | - | 400 | mW | Maximum power dissipation |
| Operating Temperature | TOPR | -40 | - | 85 | °C | Operating temperature range |
| Storage Temperature | TSTG | -65 | - | 150 | °C | Storage temperature range |
Instructions:
- Power Supply Connection: Connect the input voltage (VIN) within the specified range of 1.2V to 5.5V.
- Control Input Activation: Apply a voltage greater than 0.7V to the enable pin (VEN) to turn on the device.
- Load Connection: Ensure that the load current does not exceed 600mA to avoid overheating and potential damage.
- Thermal Management: Monitor the operating temperature to ensure it remains within the -40°C to 85°C range. Use appropriate heat sinking if necessary.
- Handling Care: Store in environments where temperatures do not exceed -65°C to 150°C to prevent damage during storage.
- Signal Integrity: Consider the propagation delay when integrating into high-speed circuits to maintain signal integrity.
For detailed specifications and additional information, refer to the official datasheet provided by the manufacturer.
(For reference only)View more about TPS2812DR on main site