| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Rated Voltage | VDSS | - | 1200 | - | V | Maximum repetitive peak off-state voltage |
| Rated Current | IT(AV) | - | 300 | - | A | Average on-state current (Tc = 110°C, f = 50 Hz, sinewave) |
| On-State Voltage | VCE(on) | 2.2 | - | 3.0 | V | On-state voltage at IC = 300 A, VGE = 15 V |
| Gate Charge | QG | - | 200 | - | nC | Total gate charge at VGE(off) = -15 V, VGE(on) = 15 V, IC = 300 A |
| Turn-on Time | ton(d) | - | 200 | - | ns | Delay time from VGE to IC (10% to 90%) |
| Rise Time | tr | - | 100 | - | ns | Time for IC to rise from 10% to 90% |
| Turn-off Time | toff | - | 150 | - | ns | Time from IC(90%) to IC(10%) |
| Fall Time | tf | - | 100 | - | ns | Time for IC to fall from 90% to 10% |
| Junction Temperature | Tj | -40 | - | 175 | °C | Operating junction temperature range |
| Storage Temperature | Tstg | -55 | - | 150 | °C | Storage temperature range |
| Case Temperature | Tc | -40 | - | 125 | °C | Operating case temperature range |
| Power Dissipation | Ptot | - | - | 1500 | W | Maximum power dissipation (Tc = 25°C) |
Instructions:
Handling and Storage:
- Store the device in a dry, cool place away from direct sunlight.
- Handle with care to avoid mechanical damage.
Mounting:
- Ensure proper heat sinking to maintain the junction temperature within the specified limits.
- Use thermal compound to enhance heat transfer between the device and the heatsink.
Electrical Connections:
- Connect the gate and source terminals correctly to avoid damage.
- Use short and thick wires to minimize inductance and resistance.
Operational Conditions:
- Do not exceed the maximum ratings for voltage, current, and temperature.
- Ensure adequate cooling to prevent thermal runaway.
Testing:
- Perform all tests under controlled conditions to avoid over-stressing the device.
- Use appropriate test equipment and follow safety guidelines.
Safety:
- Always use protective equipment when handling high-voltage or high-current circuits.
- Follow all relevant safety standards and regulations.