Parameter Description Min Typ Max Unit
Supply Voltage (VDD) Operating supply voltage range 2.7 - 5.5 V
Input Voltage Range Differential input voltage range -0.3 - VDD + 0.3 V
Output Data Rate Configurable output data rate 20 - 2400 SPS (Samples per Second)
Resolution Effective resolution - 20 - bits
Integral Nonlinearity (INL) Maximum integral nonlinearity error - ±1 - LSB
Differential Nonlinearity (DNL) Maximum differential nonlinearity error - ±1 - LSB
Offset Error Initial offset error - ±10 - μV
Gain Error Initial gain error - ±0.05 - % FS
Gain Drift Temperature coefficient of gain error - ±5 - ppm/°C
Common-Mode Rejection Ratio (CMRR) Rejection of common-mode signals 80 - 100 dB
Power Consumption Active mode power consumption - 1.2 - mA
Shutdown Current Current consumption in shutdown mode - 0.5 - μA
Operating Temperature Range Temperature range for operation -40 - 85 °C
Storage Temperature Range Temperature range for storage -65 - 150 °C

Instructions for Use

  1. Power Supply:

    • Connect the VDD pin to a stable power supply within the range of 2.7V to 5.5V.
    • Ensure the GND pin is connected to the system ground.
  2. Input Configuration:

    • Connect the differential input signals to the IN+ and IN- pins.
    • The input voltage should be within the range of -0.3V to VDD + 0.3V.
  3. Output Data Rate Configuration:

    • Set the desired output data rate using the configuration registers.
    • Valid data rates range from 20 SPS to 2400 SPS.
  4. Resolution and Accuracy:

    • The ADS1230 provides 20-bit effective resolution.
    • Ensure that the system design accounts for the specified INL and DNL errors.
  5. Calibration:

    • Perform initial calibration to correct for offset and gain errors.
    • Use the provided calibration routines or external calibration methods as needed.
  6. Power Management:

    • To reduce power consumption, use the shutdown mode by setting the appropriate register bit.
    • In shutdown mode, the current consumption is reduced to approximately 0.5 μA.
  7. Temperature Considerations:

    • Operate the device within the temperature range of -40°C to 85°C for optimal performance.
    • Store the device within the temperature range of -65°C to 150°C.
  8. Signal Integrity:

    • Use proper PCB layout techniques to minimize noise and ensure signal integrity.
    • Place decoupling capacitors close to the VDD and GND pins to filter out supply noise.
  9. Communication Interface:

    • Use the SPI interface to communicate with the ADS1230.
    • Refer to the datasheet for specific SPI communication protocols and register maps.
  10. Troubleshooting:

    • If the device does not function as expected, check the power supply, input signals, and communication lines.
    • Verify that all configuration settings are correctly set according to the application requirements.