TSR2402R

TSR2402R


Specifications
SKU
12542469
Details

BUY TSR2402R https://www.utsource.net/itm/p/12542469.html

Parameter Symbol Min Typical Max Unit Notes
Input Voltage VIN 1.8 - 5.5 V
Output Voltage VOUT - 2.4 - V Fixed
Output Current IOUT - 300 - mA Continuous
Quiescent Current IQ - 2.5 - μA Shutdown mode: 0.1 μA
Dropout Voltage VDROPOUT - 200 - mV At 300 mA load
Efficiency η - 90 - % At 3.3V in, 2.4V out, 300mA load
Operating Temperature TOPR -40 - 85 °C
Storage Temperature TSTG -65 - 150 °C
Load Regulation ΔVOUT/ΔILOAD - 0.5 - % From 0 to 300 mA
Line Regulation ΔVOUT/ΔVIN - 0.1 - %/V From 2.7 to 5.5 V
PSRR (10 Hz to 100 kHz) PSRR - 70 - dB
Ripple Rejection RR - 70 - dB

Instructions for Use:

  1. Input Connection:

    • Connect the input voltage (VIN) to the input pin. Ensure the input voltage is within the specified range (1.8V to 5.5V).
  2. Output Connection:

    • Connect the output pin (VOUT) to the load. The TSR2402R provides a fixed output voltage of 2.4V.
  3. Ground Connection:

    • Ensure a common ground connection between the input and output circuits.
  4. Capacitors:

    • Place a 1 μF ceramic capacitor close to the input pin to stabilize the input voltage.
    • Place a 1 μF ceramic capacitor close to the output pin to stabilize the output voltage.
  5. Thermal Considerations:

    • Ensure adequate heat dissipation if operating at high output currents or in high ambient temperatures.
  6. Shutdown Mode:

    • To enter shutdown mode, pull the SHDN pin low. The quiescent current will drop to 0.1 μA in this mode.
  7. PCB Layout:

    • Keep the PCB traces short and wide to minimize inductance and resistance.
    • Use a ground plane to improve thermal performance and reduce noise.
  8. Storage and Handling:

    • Store the device in a dry, cool environment.
    • Handle with care to avoid static damage. Use proper ESD protection.
  9. Testing:

    • Before final assembly, test the regulator with a known load to ensure it meets the required specifications.
  10. Compliance:

    • Ensure that the design complies with relevant safety and regulatory standards for your application.
(For reference only)

View more about TSR2402R on main site