BUY TLP624 https://www.utsource.net/itm/p/12542478.html
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Forward Voltage | VF | IF = 10 mA | - | 1.2 | 1.5 | V |
Peak Forward Current | IFP | tp = 1 ms, single pulse | - | - | 1.0 | A |
Reverse Voltage | VR | IR = 5 mA | - | - | 5 | V |
Output Current | IOT | TLP624-1: VDD = 5V, R = 100惟 | - | 30 | - | mA |
Propagation Delay Time | tPD | VOH = 2.0V, VOL = 0.8V | - | 0.7 | 1.3 | 渭s |
Rise Time | tr | VOH = 2.0V, VOL = 0.8V | - | 0.2 | 0.5 | 渭s |
Fall Time | tf | VOH = 2.0V, VOL = 0.8V | - | 0.2 | 0.5 | 渭s |
Instructions for Use:
- Mounting Orientation: Ensure the device is mounted with the correct orientation to avoid damage and ensure proper operation.
- Heat Dissipation: Consider adequate heat dissipation if operating at high currents or in high ambient temperatures.
- Voltage Handling: Do not exceed the maximum reverse voltage ratings to prevent component failure.
- Current Limitation: Keep the forward current within specified limits to avoid overheating and potential damage.
- Pulse Width: For peak forward current tests, use pulses no longer than 1 ms to avoid thermal overload.
- Output Load: Ensure that the output load resistance and supply voltage are within the recommended range to achieve optimal performance.
- Timing Parameters: Account for propagation delay, rise time, and fall time in system timing designs to ensure reliable signal transmission.
For detailed specifications and further instructions, refer to the official datasheet provided by the manufacturer.
(For reference only)View more about TLP624 on main site