TOP234YN

TOP234YN

Category: IC Chips

Specifications
SKU
12542691
Details

BUY TOP234YN https://www.utsource.net/itm/p/12542691.html

Parameter Symbol Min Typ Max Unit Description
Input Voltage Range VIN 85 - 265 VAC Operating input voltage range
Output Power PO - 100 - W Maximum output power
Switching Frequency fSW 70 132 190 kHz Switching frequency range
Efficiency η - 88 - % Typical efficiency at full load
Power Factor PF - 0.95 - - Typical power factor at full load
No-Load Input Power PNL - 0.15 - W Typical no-load input power
Standby Power PSBY - 0.3 - W Typical standby power
Operating Temperature Toper -40 - 85 °C Operating temperature range
Storage Temperature Tstg -55 - 125 °C Storage temperature range
Humidity RH - - 95 % Relative humidity, non-condensing
Isolation Voltage VIORM - - 4000 VAC Input to output isolation voltage (1 minute)
Leakage Current IL - 0.5 - mA Typical leakage current at 265VAC input

Instructions for Use:

  1. Input Connection:

    • Connect the AC input to the designated pins on the TOP234YN. Ensure the input voltage is within the specified range (85VAC to 265VAC).
  2. Output Configuration:

    • The output configuration should be designed to handle the maximum output power of 100W. Ensure proper heat dissipation and load matching.
  3. Switching Frequency:

    • The switching frequency can vary between 70kHz and 190kHz. Optimize the design for the typical frequency of 132kHz for best performance.
  4. Efficiency and Power Factor:

    • The device is designed to achieve high efficiency (up to 88%) and a power factor of 0.95 at full load. Verify these parameters during testing.
  5. No-Load and Standby Power:

    • Ensure that the no-load input power does not exceed 0.15W and the standby power does not exceed 0.3W to meet energy efficiency standards.
  6. Temperature and Environmental Conditions:

    • Operate the device within the temperature range of -40°C to 85°C. Store it in an environment with temperatures between -55°C and 125°C and relative humidity up to 95%.
  7. Isolation and Safety:

    • Ensure that the input to output isolation voltage is at least 4000VAC for 1 minute to prevent electrical hazards. Keep the leakage current below 0.5mA for safety.
  8. Mounting and Handling:

    • Mount the TOP234YN on a suitable heatsink to manage thermal dissipation. Handle the device with care to avoid damage to the pins and internal components.
  9. Testing and Validation:

    • Perform thorough testing under various conditions to ensure the device meets all performance and safety specifications.
  10. Compliance:

    • Ensure compliance with relevant safety and regulatory standards for the application and region where the device will be used.
(For reference only)

View more about TOP234YN on main site