HCPL-V601

HCPL-V601


Specifications
Details

BUY HCPL-V601 https://www.utsource.net/itm/p/12542749.html

Parameter Symbol Min Typ Max Unit Description
Input Current IF(ON) 1.0 - 5.0 mA Forward current for guaranteed turn-on
Input Current IF(OFF) - 0.1 0.2 mA Maximum forward current for guaranteed turn-off
Propagation Delay Time tPLH 4.0 6.0 8.0 μs Propagation delay time (Low to High output transition)
Propagation Delay Time tPHL 4.0 6.0 8.0 μs Propagation delay time (High to Low output transition)
Pulse Width Distortion tPWD - 1.0 2.0 μs Difference between tPLH and tPHL
Isolation Voltage VIORM - - 700 V Repetitive peak isolation voltage
Common Mode Transient Immunity CMTI - 25 - kV/μs Common mode transient immunity
Operating Temperature TOPR -40 - 85 °C Operating temperature range
Storage Temperature TSTG -55 - 125 °C Storage temperature range

Instructions:

  1. Power Supply Connection: Ensure the HCPL-V601 is powered within its specified operating voltage range to avoid damage.
  2. Input Current Setting: Set the input current within the specified limits (1.0mA to 5.0mA for turn-on, below 0.2mA for turn-off) to ensure proper operation.
  3. Signal Integrity: Given the propagation delays and pulse width distortion, design your circuit considering these parameters to maintain signal integrity.
  4. Isolation Considerations: Handle and apply the device carefully in circuits where isolation voltages up to 700V may be present.
  5. Temperature Management: Operate the device within the recommended temperature ranges to prevent thermal stress or failure.
  6. Handling Precautions: Use appropriate ESD protection measures when handling the component to prevent damage from static electricity.
(For reference only)

View more about HCPL-V601 on main site