Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Breakdown Voltage | BV | - | - | 700 | V | Maximum repetitive peak reverse voltage |
Continuous Drain Current | ID | - | - | 400 | A | Continuous drain current at Tc = 25°C |
Power Dissipation | PD | - | - | 120 | kW | Maximum power dissipation |
Junction Temperature | Tj | -20 | - | 175 | °C | Operating junction temperature range |
Storage Temperature | Tstg | -65 | - | 150 | °C | Storage temperature range |
Gate Charge | Qg | - | 120 | - | nC | Total gate charge at VGS = 15V, IDS = 200A |
Input Capacitance | Ciss | - | 3800 | - | pF | Input capacitance at VDS = 500V, VGS = 0V |
Output Capacitance | Coff | - | 290 | - | pF | Output capacitance at VDS = 500V, IDS = 0A |
Reverse Transfer Capacitance | Crss | - | 900 | - | pF | Reverse transfer capacitance at VDS = 500V, IDS = 0A |
Turn-on Delay Time | td(on) | - | 30 | - | ns | Turn-on delay time at VGS = 15V, IDS = 200A |
Rise Time | tr | - | 60 | - | ns | Rise time at VGS = 15V, IDS = 200A |
Turn-off Delay Time | td(off) | - | 35 | - | ns | Turn-off delay time at VGS = -15V, IDS = 200A |
Fall Time | tf | - | 70 | - | ns | Fall time at VGS = -15V, IDS = 200A |
Instructions for Use:
Mounting and Handling:
- Ensure proper handling to avoid damage to the device.
- Use appropriate heat sinks to manage thermal dissipation.
Electrical Connections:
- Connect the drain (D), source (S), and gate (G) terminals correctly.
- Ensure all connections are secure and free from shorts or open circuits.
Thermal Management:
- The maximum junction temperature (Tj) should not exceed 175°C.
- Use thermal paste and heatsinks to enhance heat dissipation.
Gate Drive:
- Apply the correct gate voltage (VGS) to ensure reliable operation.
- Use a gate resistor to control switching speed and reduce electromagnetic interference (EMI).
Overcurrent Protection:
- Implement overcurrent protection to prevent damage due to excessive current.
- Monitor the drain current (ID) to ensure it does not exceed the maximum rating.
Storage and Transportation:
- Store the device in a dry, cool place within the specified storage temperature range (-65°C to 150°C).
- Handle with care during transportation to avoid mechanical stress.
Testing:
- Perform initial testing under controlled conditions to verify performance.
- Use appropriate test equipment and follow safety guidelines.
Compliance:
- Ensure the device is used in compliance with relevant standards and regulations.
- Refer to the datasheet for detailed specifications and application notes.
View more about 2MBI400U7H-120-52 on main site