Details
BUY P6KE130CA https://www.utsource.net/itm/p/12543114.html
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Reverse Standoff Voltage | VRWM | - | 130 | - | V | Maximum reverse voltage that can be applied continuously without significant current flow |
Peak Pulse Current | Ipp | - | 29.8 | - | A | Maximum peak pulse current for 8.3 ms single pulses at 25掳C |
Clamping Voltage | VC | - | 222 | - | V | Maximum voltage across the device when conducting the peak pulse current |
Maximum Reverse Leakage Current | IR | - | 1 | - | 渭A | Maximum reverse leakage current at VRWM |
Junction Capacitance | CJ | - | 1000 | - | pF | Capacitance between the terminals at 0V bias and 1 MHz frequency |
Operating Temperature Range | Toper | -40 | - | 125 | 掳C | Temperature range over which the device is designed to operate |
Storage Temperature Range | Tstg | -55 | - | 150 | 掳C | Temperature range over which the device can be stored without damage |
Instructions:
Mounting:
- Ensure proper mounting to avoid mechanical stress on the leads.
- Use appropriate soldering techniques to prevent thermal damage.
Handling:
- Handle with care to avoid static discharge, which can damage the device.
- Store in a dry, cool place within the specified storage temperature range.
Application:
- Ensure the reverse standoff voltage (VRWM) is not exceeded during normal operation.
- The clamping voltage (VC) should be considered when designing the circuit to protect downstream components.
- The peak pulse current (Ipp) should not be exceeded to avoid damage or reduced lifespan.
Testing:
- Test the device under controlled conditions to ensure it meets the specified parameters.
- Use a suitable test setup to measure reverse leakage current (IR) and junction capacitance (CJ).
Safety:
- Follow all relevant safety guidelines and regulations when handling and using the device.
- Ensure proper grounding and isolation to prevent electrical hazards.
View more about P6KE130CA on main site