TLE4252D

TLE4252D


Specifications
SKU
12543768
Details

BUY TLE4252D https://www.utsource.net/itm/p/12543768.html

Below is the parameter table and instructions for the TLE4252D, a Hall sensor from Infineon Technologies.

TLE4252D Parameter Table

Parameter Symbol Min Typ Max Unit Condition
Supply Voltage VCC 4.5 5.0 5.5 V
Output High Level VOH - 4.7 - V IOL = 1 mA
Output Low Level VOL - 0.4 - V IOH = 1 mA
Output Leakage Current (High) IOLH - 10 - μA VOUT = 5V
Output Leakage Current (Low) IOLL - -10 - μA VOUT = 0V
Magnetic Sensitivity BOP - 20 - mT Operate Point
Magnetic Sensitivity BRP - -20 - mT Release Point
Operating Temperature Range TOP -40 - 125 °C
Storage Temperature Range TSTG -40 - 150 °C
Quiescent Current IQ - 3.5 - mA VCC = 5V
Response Time tR - 100 - μs

Instructions for TLE4252D

  1. Supply Voltage:

    • Ensure the supply voltage (VCC) is within the range of 4.5V to 5.5V. The typical operating voltage is 5.0V.
  2. Output Levels:

    • When the magnetic field exceeds the operate point (BOP), the output will switch to a low level (VOL ≈ 0.4V).
    • When the magnetic field falls below the release point (BRP), the output will switch to a high level (VOH ≈ 4.7V).
  3. Magnetic Sensitivity:

    • The sensor will switch states when the magnetic field strength reaches the operate point (BOP ≈ 20 mT) or the release point (BRP ≈ -20 mT).
  4. Temperature Range:

    • The device is designed to operate within a temperature range of -40°C to 125°C. Store the device within a temperature range of -40°C to 150°C.
  5. Quiescent Current:

    • The quiescent current (IQ) is typically 3.5 mA at a supply voltage of 5V.
  6. Response Time:

    • The response time (tR) is approximately 100 μs, which is the time it takes for the output to switch states after a change in the magnetic field.
  7. Installation:

    • Mount the sensor in a location where it can detect the magnetic field without interference from other magnetic sources.
    • Ensure that the sensor is properly grounded to avoid noise and interference.
  8. Handling:

    • Handle the device with care to avoid mechanical stress or damage.
    • Follow standard ESD (Electrostatic Discharge) precautions to prevent damage to the device.
  9. Testing:

    • Test the device using a known magnetic field to verify its operation before integrating it into a larger system.

By following these parameters and instructions, you can ensure reliable operation of the TLE4252D Hall sensor in your application.

(For reference only)

View more about TLE4252D on main site