Details
BUY TLE4252D https://www.utsource.net/itm/p/12543768.html
Below is the parameter table and instructions for the TLE4252D, a Hall sensor from Infineon Technologies.
TLE4252D Parameter Table
| Parameter | Symbol | Min | Typ | Max | Unit | Condition |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 4.5 | 5.0 | 5.5 | V | |
| Output High Level | VOH | - | 4.7 | - | V | IOL = 1 mA |
| Output Low Level | VOL | - | 0.4 | - | V | IOH = 1 mA |
| Output Leakage Current (High) | IOLH | - | 10 | - | μA | VOUT = 5V |
| Output Leakage Current (Low) | IOLL | - | -10 | - | μA | VOUT = 0V |
| Magnetic Sensitivity | BOP | - | 20 | - | mT | Operate Point |
| Magnetic Sensitivity | BRP | - | -20 | - | mT | Release Point |
| Operating Temperature Range | TOP | -40 | - | 125 | °C | |
| Storage Temperature Range | TSTG | -40 | - | 150 | °C | |
| Quiescent Current | IQ | - | 3.5 | - | mA | VCC = 5V |
| Response Time | tR | - | 100 | - | μs |
Instructions for TLE4252D
Supply Voltage:
- Ensure the supply voltage (VCC) is within the range of 4.5V to 5.5V. The typical operating voltage is 5.0V.
Output Levels:
- When the magnetic field exceeds the operate point (BOP), the output will switch to a low level (VOL ≈ 0.4V).
- When the magnetic field falls below the release point (BRP), the output will switch to a high level (VOH ≈ 4.7V).
Magnetic Sensitivity:
- The sensor will switch states when the magnetic field strength reaches the operate point (BOP ≈ 20 mT) or the release point (BRP ≈ -20 mT).
Temperature Range:
- The device is designed to operate within a temperature range of -40°C to 125°C. Store the device within a temperature range of -40°C to 150°C.
Quiescent Current:
- The quiescent current (IQ) is typically 3.5 mA at a supply voltage of 5V.
Response Time:
- The response time (tR) is approximately 100 μs, which is the time it takes for the output to switch states after a change in the magnetic field.
Installation:
- Mount the sensor in a location where it can detect the magnetic field without interference from other magnetic sources.
- Ensure that the sensor is properly grounded to avoid noise and interference.
Handling:
- Handle the device with care to avoid mechanical stress or damage.
- Follow standard ESD (Electrostatic Discharge) precautions to prevent damage to the device.
Testing:
- Test the device using a known magnetic field to verify its operation before integrating it into a larger system.
By following these parameters and instructions, you can ensure reliable operation of the TLE4252D Hall sensor in your application.