IRS2092S

IRS2092S


Specifications
SKU
12543788
Details

BUY IRS2092S https://www.utsource.net/itm/p/12543788.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage Vcc - 10 - 60 V
Gate Drive Voltage (High Side) VGH - 10 - 60 V
Gate Drive Voltage (Low Side) VGL - 0 - 15 V
Gate Drive Current (Source) IGHS - - 1.5 2.0 A
Gate Drive Current (Sink) IGLS - - 1.5 2.0 A
Maximum Operating Temperature Toper - -40 - 150 °C
Storage Temperature Tstg - -65 - 150 °C
Propagation Delay Time (High to Low) tpdHL Vcc = 15V, RL = 10Ω 75 - - ns
Propagation Delay Time (Low to High) tpdLH Vcc = 15V, RL = 10Ω 75 - - ns
Dead Time td Vcc = 15V, RL = 10Ω 100 - - ns
Maximum Continuous Output Current Iout - - 1.5 2.0 A

Instructions for Use:

  1. Supply Voltage (Vcc):

    • Ensure the supply voltage is within the range of 10V to 60V.
    • Exceeding the maximum supply voltage can damage the device.
  2. Gate Drive Voltages:

    • The high-side gate drive voltage (VGH) should be between 10V and 60V.
    • The low-side gate drive voltage (VGL) should be between 0V and 15V.
    • Ensure the gate drive voltages are within these ranges to avoid damaging the MOSFETs.
  3. Gate Drive Currents:

    • The source and sink currents for the gate drivers (IGHS and IGLS) should not exceed 2.0A.
    • Typical values are around 1.5A, but the device can handle up to 2.0A.
  4. Temperature Ranges:

    • The operating temperature (Toper) should be between -40°C and 150°C.
    • The storage temperature (Tstg) should be between -65°C and 150°C.
    • Ensure the device is not exposed to temperatures outside these ranges to prevent damage.
  5. Propagation Delays:

    • The propagation delay times (tpdHL and tpdLH) are typically 75ns when Vcc = 15V and RL = 10Ω.
    • These delays ensure proper timing in switching applications.
  6. Dead Time:

    • The dead time (td) is typically 100ns when Vcc = 15V and RL = 10Ω.
    • This ensures that both high-side and low-side MOSFETs do not conduct simultaneously, preventing shoot-through current.
  7. Maximum Continuous Output Current:

    • The maximum continuous output current (Iout) is 2.0A.
    • Ensure the load does not draw more than this current to avoid overheating and potential damage.
  8. Handling and Installation:

    • Handle the device with care to avoid static discharge.
    • Follow proper PCB layout guidelines to minimize parasitic inductance and capacitance.
    • Ensure good thermal management to keep the device within its operating temperature range.

By following these parameters and instructions, you can ensure reliable operation of the IRS2092S in your application.

(For reference only)

View more about IRS2092S on main site