Details
BUY ULN2004APG https://www.utsource.net/itm/p/12543789.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 4.5 | - | 55 | V | Operating voltage range |
| Continuous Output Current | IO | - | 500 | - | mA | Maximum continuous output current per channel |
| Peak Output Current | IOPK | - | 600 | - | mA | Maximum peak output current per channel (10% duty cycle) |
| Input Current | II | - | 15 | 30 | μA | Input current at VI = 5V |
| Input Voltage | VI | - | 1.5 | 5 | V | Input voltage for logic high |
| Output Saturation Voltage | VCE(sat) | - | 1.0 | 1.4 | V | Output saturation voltage at IO = 500mA |
| Thermal Resistance | RθJA | - | 75 | - | °C/W | Junction-to-ambient thermal resistance |
| Storage Temperature Range | TSTG | -65 | - | 150 | °C | Temperature range for storage and operation |
| Operating Temperature Range | TA | -40 | - | 85 | °C | Ambient temperature range for operation |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (VCC) is within the specified range (4.5V to 55V).
- Connect the positive terminal of the power supply to pin 10 and the negative terminal to pin 9.
Input Connections:
- Connect the input signals to pins 1 through 7.
- The input voltage should be between 1.5V and 5V for a logic high.
- Ensure the input current does not exceed 30μA.
Output Connections:
- Connect the load to the output pins (pins 16 through 10, excluding pin 9).
- The maximum continuous output current per channel is 500mA.
- For peak currents up to 600mA, ensure the duty cycle does not exceed 10%.
Heat Dissipation:
- The device has a thermal resistance of 75°C/W. Consider using a heatsink if the power dissipation is significant.
- Ensure the junction temperature does not exceed 150°C.
Temperature Range:
- The device can operate in ambient temperatures ranging from -40°C to 85°C.
- Store the device in temperatures ranging from -65°C to 150°C.
Protection:
- Each output channel includes a flyback diode to protect against inductive loads.
- Ensure proper grounding and use appropriate decoupling capacitors to stabilize the power supply.
Handling:
- Handle the device with care to avoid static damage.
- Follow standard ESD precautions when handling the device.
By following these guidelines, you can ensure reliable and efficient operation of the ULN2004APG.
(For reference only)View more about ULN2004APG on main site