Details
BUY OB2283KMP https://www.utsource.net/itm/p/12554023.html
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Supply Voltage | VDD | 1.6 | - | 5.5 | V | Operating supply voltage range |
Output Current | IOUT | - | 100 | - | mA | Maximum continuous output current |
Quiescent Current | IQ | - | 20 | - | μA | Typical quiescent current at VDD = 3V, TA = 25°C |
Dropout Voltage | VDROPOUT | - | 200 | - | mV | Typical dropout voltage at IOUT = 100mA, VDD = 3V |
Load Regulation | - | - | 0.2 | - | % | Load regulation from 0 to 100mA, VDD = 3V, TA = 25°C |
Line Regulation | - | - | 0.2 | - | % | Line regulation from 1.6V to 5.5V, IOUT = 100mA, TA = 25°C |
Thermal Shutdown | TSD | - | 160 | - | °C | Thermal shutdown temperature |
Operating Temperature | TOPR | -40 | - | 85 | °C | Operating ambient temperature range |
Storage Temperature | TSTG | -65 | - | 150 | °C | Storage temperature range |
Output Voltage | VOUT | - | 1.8 | - | V | Nominal output voltage |
Instructions for Use:
Supply Voltage (VDD):
- Ensure the supply voltage is within the specified range (1.6V to 5.5V) to avoid damage or improper operation.
Output Current (IOUT):
- The device can provide up to 100mA continuously. Exceeding this limit may cause thermal shutdown or damage.
Quiescent Current (IQ):
- The typical quiescent current is 20μA at 3V supply voltage and 25°C ambient temperature. This is important for low-power applications.
Dropout Voltage (VDROPOUT):
- The typical dropout voltage is 200mV at 100mA output current and 3V supply voltage. This ensures efficient operation even when the input voltage is close to the output voltage.
Load and Line Regulation:
- Both load and line regulation are specified as 0.2%, indicating good stability under varying load and input conditions.
Thermal Shutdown (TSD):
- The device will shut down if the internal temperature exceeds 160°C to prevent damage. Ensure adequate heat dissipation in high-current applications.
Operating and Storage Temperature:
- The device operates reliably between -40°C and 85°C and can be stored between -65°C and 150°C.
Output Voltage (VOUT):
- The nominal output voltage is 1.8V. Ensure this matches the requirements of your application.
Mounting and Handling:
- Follow standard surface mount technology (SMT) procedures for mounting. Avoid excessive heat and mechanical stress during soldering.
Capacitors:
- Use appropriate input and output capacitors as recommended in the datasheet to ensure stable operation and filter out noise.
For detailed application notes and further information, refer to the full datasheet provided by the manufacturer.
(For reference only)View more about OB2283KMP on main site