IRLR3110ZTRPBF

IRLR3110ZTRPBF


Specifications
SKU
12555257
Details

BUY IRLR3110ZTRPBF https://www.utsource.net/itm/p/12555257.html

Parameter Symbol Min Typ Max Unit Conditions
Drain-Source Voltage VDS - 55 - V
Gate-Source Voltage VGS -20 - 20 V
Continuous Drain Current ID - 14 - A TC = 25°C
Pulse Drain Current IDpeak - 60 - A tp = 10 μs, IG = 10 A
Total Power Dissipation PTOT - 49 - W TC = 25°C
Junction Temperature TJ - - 150 °C
Storage Temperature Range TSTG -65 - 150 °C
Thermal Resistance, Junction to Ambient RθJA - 62 - °C/W
On-State Resistance RDS(on) 2.2 - 3.0 VGS = 10 V, ID = 14 A, TA = 25°C
Input Capacitance Ciss - 1280 - pF VDS = 10 V, f = 1 MHz
Output Capacitance Coss - 100 - pF VDS = 10 V, f = 1 MHz
Reverse Transfer Capacitance Crss - 220 - pF VDS = 10 V, f = 1 MHz
Gate Charge QG - 14 - nC VGS = 10 V, ID = 14 A
Turn-On Delay Time td(on) - 17 - ns VGS = 10 V, ID = 14 A, RG = 1 Ω
Rise Time tr - 25 - ns VGS = 10 V, ID = 14 A, RG = 1 Ω
Turn-Off Delay Time td(off) - 20 - ns VGS = 10 V, ID = 14 A, RG = 1 Ω
Fall Time tf - 25 - ns VGS = 10 V, ID = 14 A, RG = 1 Ω

Instructions for Use:

  1. Handling Precautions:

    • Avoid exposing the device to excessive static electricity.
    • Ensure proper heat sinking to manage thermal resistance and junction temperature.
  2. Mounting and Soldering:

    • Use appropriate soldering techniques to avoid thermal shock.
    • Ensure good electrical and thermal connections.
  3. Electrical Connections:

    • Connect the drain (D), source (S), and gate (G) terminals correctly.
    • Use a suitable gate resistor to control switching speed and reduce electromagnetic interference (EMI).
  4. Operating Conditions:

    • Operate within the specified voltage and current limits to prevent damage.
    • Monitor the junction temperature to ensure it does not exceed 150°C.
  5. Storage:

    • Store in a dry, cool place away from direct sunlight and corrosive environments.
    • Follow recommended storage temperature ranges to maintain reliability.
  6. Testing and Validation:

    • Perform initial testing under controlled conditions to verify performance.
    • Regularly inspect and test the device to ensure continued reliable operation.
  7. Safety:

    • Always follow safety guidelines when handling high voltages and currents.
    • Use appropriate personal protective equipment (PPE) as needed.
(For reference only)