| Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Drain-Source Voltage | VDS | - | 55 | - | V | |
| Gate-Source Voltage | VGS | -20 | - | 20 | V | |
| Continuous Drain Current | ID | - | 14 | - | A | TC = 25°C |
| Pulse Drain Current | IDpeak | - | 60 | - | A | tp = 10 μs, IG = 10 A |
| Total Power Dissipation | PTOT | - | 49 | - | W | TC = 25°C |
| Junction Temperature | TJ | - | - | 150 | °C | |
| Storage Temperature Range | TSTG | -65 | - | 150 | °C | |
| Thermal Resistance, Junction to Ambient | RθJA | - | 62 | - | °C/W | |
| On-State Resistance | RDS(on) | 2.2 | - | 3.0 | mΩ | VGS = 10 V, ID = 14 A, TA = 25°C |
| Input Capacitance | Ciss | - | 1280 | - | pF | VDS = 10 V, f = 1 MHz |
| Output Capacitance | Coss | - | 100 | - | pF | VDS = 10 V, f = 1 MHz |
| Reverse Transfer Capacitance | Crss | - | 220 | - | pF | VDS = 10 V, f = 1 MHz |
| Gate Charge | QG | - | 14 | - | nC | VGS = 10 V, ID = 14 A |
| Turn-On Delay Time | td(on) | - | 17 | - | ns | VGS = 10 V, ID = 14 A, RG = 1 Ω |
| Rise Time | tr | - | 25 | - | ns | VGS = 10 V, ID = 14 A, RG = 1 Ω |
| Turn-Off Delay Time | td(off) | - | 20 | - | ns | VGS = 10 V, ID = 14 A, RG = 1 Ω |
| Fall Time | tf | - | 25 | - | ns | VGS = 10 V, ID = 14 A, RG = 1 Ω |
Instructions for Use:
Handling Precautions:
- Avoid exposing the device to excessive static electricity.
- Ensure proper heat sinking to manage thermal resistance and junction temperature.
Mounting and Soldering:
- Use appropriate soldering techniques to avoid thermal shock.
- Ensure good electrical and thermal connections.
Electrical Connections:
- Connect the drain (D), source (S), and gate (G) terminals correctly.
- Use a suitable gate resistor to control switching speed and reduce electromagnetic interference (EMI).
Operating Conditions:
- Operate within the specified voltage and current limits to prevent damage.
- Monitor the junction temperature to ensure it does not exceed 150°C.
Storage:
- Store in a dry, cool place away from direct sunlight and corrosive environments.
- Follow recommended storage temperature ranges to maintain reliability.
Testing and Validation:
- Perform initial testing under controlled conditions to verify performance.
- Regularly inspect and test the device to ensure continued reliable operation.
Safety:
- Always follow safety guidelines when handling high voltages and currents.
- Use appropriate personal protective equipment (PPE) as needed.
View more about IRLR3110ZTRPBF on main site