Details
BUY BQ24751ARHD https://www.utsource.net/itm/p/12591031.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | Continuous | 4.5 | 28 | V | |
| Charging Current | ICHG | 1.5 | 3.0 | A | ||
| Battery Float Voltage | VFB | 4.2 | 4.2 | V | ||
| System Voltage | VOUT | 3.0 | 5.5 | V | ||
| Efficiency | η | VIN = 12V, IOUT = 1A | 88 | % | ||
| Operating Temperature | TOPR | Storage | -40 | 85 | °C | |
| Shutdown Current | ISD | VIN = 24V | 60 | μA |
Instructions for BQ24751ARHD
Input Connection:
- Connect the input voltage (VIN) to a power source within the range of 4.5V to 28V.
Output Configuration:
- Set the system output voltage (VOUT) according to your application requirements, ensuring it stays within 3.0V to 5.5V.
Charging Parameters:
- Configure the charging current (ICHG) up to a maximum of 3.0A depending on the battery specifications.
- Set the battery float voltage (VFB) typically to 4.2V for lithium-ion batteries.
Thermal Management:
- Ensure the device operates within the temperature range of -40°C to 85°C for optimal performance and longevity.
Efficiency Considerations:
- For best efficiency, operate the device with an input voltage around 12V when delivering 1A of output current.
Shutdown Mode:
- The device enters shutdown mode at very low currents, consuming less than 60μA when not in use.
Safety Precautions:
- Always adhere to the maximum ratings provided to prevent damage to the component.
- Implement appropriate circuit protection measures such as fuses and transient voltage suppressors.
View more about BQ24751ARHD on main site