EL2186CS

EL2186CS


Specifications
Details

BUY EL2186CS https://www.utsource.net/itm/p/12591212.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage Vcc Operating 4.5 30 V
Output Current Iout Continuous 1.5 A
Peak Output Current Ipk Pulse 3 A
Dropout Voltage Vdo Iout = 1.5A 2.3 V
Quiescent Current Iq Vout = 5V, No load 8 mA
Line Regulation Vcc from 4.75 to 30V 0.5 %
Load Regulation Iout from 0 to 1.5A 0.5 %
Thermal Shutdown TSD 160 °C

Instructions for EL2186CS:

  1. Supply Voltage:

    • Ensure the input voltage is within the range of 4.5V to 30V to avoid damage or improper operation.
  2. Output Current:

    • The device can supply a continuous output current up to 1.5A. For higher currents, consider heat dissipation requirements.
  3. Peak Current Handling:

    • Can handle peak currents up to 3A in short pulses. Avoid prolonged exposure to peak currents to prevent overheating.
  4. Dropout Voltage:

    • The dropout voltage is approximately 2.3V at full load (1.5A). Ensure the input voltage is sufficiently higher than the desired output voltage by this margin.
  5. Quiescent Current:

    • At no load and with an output voltage of 5V, the quiescent current is typically 8mA. This should be factored into power budget calculations.
  6. Regulation:

    • Both line and load regulation are specified at 0.5%. This ensures stable output voltage under varying input conditions and load demands.
  7. Thermal Protection:

    • The device includes thermal shutdown protection that activates around 160°C. Ensure adequate cooling if operating near maximum current or in high ambient temperatures.
  8. Installation:

    • Mount on a heatsink if operating near the maximum output current to enhance thermal performance.
    • Place close to the load to minimize trace resistance and improve stability.
  9. Capacitors:

    • Use appropriate input and output capacitors as recommended in the datasheet to ensure stability and transient response.
(For reference only)

View more about EL2186CS on main site