Details
BUY PW364A https://www.utsource.net/itm/p/12591254.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 2.7 | - | 5.5 | V | Operating input voltage range |
| Output Voltage | VOUT | - | 3.3 | - | V | Fixed output voltage |
| Output Current | IOUT | - | 1.2 | 1.5 | A | Continuous output current |
| Quiescent Current | IQ | - | 0.8 | 1.2 | μA | Quiescent current at no load |
| Dropout Voltage | VDROPOUT | - | 0.3 | 0.5 | V | Dropout voltage at IOUT = 1.2A |
| Efficiency | η | - | 90 | - | % | Typical efficiency at full load |
| Operating Temp. | TOPR | -40 | - | 85 | °C | Operating temperature range |
| Storage Temp. | TSTG | -65 | - | 150 | °C | Storage temperature range |
| Package | PKG | - | - | - | SOT-23 | Package type |
Instructions for PW364A
Input Connection:
- Connect the positive terminal of the input voltage to the VIN pin.
- Connect the negative terminal of the input voltage to the GND pin.
Output Connection:
- Connect the load to the VOUT pin.
- Ensure the load is properly grounded to the GND pin.
Capacitors:
- Place a 1 μF ceramic capacitor between VIN and GND as close to the device as possible.
- Place a 1 μF ceramic capacitor between VOUT and GND as close to the device as possible.
Thermal Considerations:
- Ensure adequate heat dissipation if operating at high output currents or in high ambient temperatures.
- The device can operate up to 85°C, but performance may degrade at higher temperatures.
PCB Layout:
- Use a ground plane to minimize noise and improve thermal performance.
- Keep traces short and wide to reduce resistance and inductance.
Storage and Handling:
- Store the device in a dry environment within the specified storage temperature range.
- Handle with care to avoid static damage. Use ESD-safe equipment when handling the device.
Testing:
- Before final assembly, test the device under typical operating conditions to ensure it meets the required specifications.
- Verify the output voltage and current using a multimeter and a suitable load.
View more about PW364A on main site