Details
BUY UC3524AN https://www.utsource.net/itm/p/12591449.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | - | 10 | - | 40 | V |
| Output Current Limit | IOL | Vout = 5V | 1.5 | - | 2.5 | A |
| Operating Temperature | Topr | - | -40 | - | 125 | °C |
| Reference Voltage | Vref | ILIM pin shorted to ground | 2.5 | - | 2.5 | V |
| Duty Cycle Range | D | - | 0 | - | 100 | % |
| Switching Frequency | fsw | External resistor | 10 | - | 500 | kHz |
| Error Amplifier Gain | Aea | - | 10 | - | 100 | dB |
Instructions for UC3524AN
Power Supply Connection:
- Connect the supply voltage (Vcc) between 10V and 40V to the appropriate pins of the UC3524AN.
Output Configuration:
- Ensure the output current limit is set appropriately using external components, typically a resistor or inductor, to stay within the 1.5A to 2.5A range.
Temperature Considerations:
- Operate the device within the temperature range of -40°C to 125°C to ensure reliable performance.
Reference Voltage Setup:
- For accurate regulation, connect the ILIM pin to ground to achieve a stable reference voltage of 2.5V.
Duty Cycle Adjustment:
- Adjust the duty cycle as needed within the 0% to 100% range using control logic or external components.
Frequency Setting:
- Set the switching frequency by connecting an appropriate external resistor, ensuring it falls within the 10kHz to 500kHz range.
Error Amplifier Tuning:
- The error amplifier gain can be adjusted via external components to achieve the desired gain between 10dB and 100dB for optimal performance.
Note: Always refer to the specific application notes and detailed datasheet provided by the manufacturer for precise setup and troubleshooting.
(For reference only)View more about UC3524AN on main site