Parameter | Description | Value |
---|---|---|
Device Type | Dual 16-Bit Nonvolatile Static RAM with Battery Backup | - |
Data Retention Time | Data retention without power (battery-backed) | 10 years |
Operating Voltage | VCC Supply Voltage | 4.5V to 5.5V |
Battery Voltage | Battery Backup Voltage | 2.7V to 3.6V |
Memory Size | Total Memory Size | 32 kbits (2 x 16 kbits) |
Organization | Memory Organization | 2 x 16 x 8 |
Access Time | Maximum Access Time | 70 ns |
Standby Current | Supply Current in Standby Mode | 10 μA (max) |
Active Current | Supply Current in Active Mode | 20 mA (max) |
Write Cycle Time | Maximum Write Cycle Time | 100 μs |
Operating Temperature | Operating Temperature Range | -40°C to +85°C |
Package | Package Type | SOIC-16 |
Instructions for Use
Power Supply Connection:
- Connect the VCC pin to a 4.5V to 5.5V power supply.
- Connect the battery backup pin (Vbat) to a 2.7V to 3.6V battery.
Address and Data Lines:
- Connect the address lines (A0-A15) to the desired memory locations.
- Connect the data lines (D0-D7) to the data bus.
Control Signals:
- Chip Select (CS): Low to enable the device.
- Write Enable (WE): Low to write data to the selected memory location.
- Output Enable (OE): Low to read data from the selected memory location.
Write Operation:
- Set CS and WE low.
- Apply the desired address to the address lines.
- Apply the data to be written to the data lines.
- Wait for the write cycle time (100 μs) before setting WE high.
Read Operation:
- Set CS and OE low.
- Apply the desired address to the address lines.
- Data will be available on the data lines after the access time (70 ns).
Battery Backup:
- Ensure the battery is connected to maintain data retention during power loss.
- The device will automatically switch to battery power when VCC falls below the threshold.
Storage and Handling:
- Store the device in a dry environment to prevent moisture damage.
- Handle with care to avoid static discharge which can damage the device.
End of Life:
- When the battery reaches its end of life (data retention less than 10 years), replace the battery or the entire module if necessary.