Details
BUY CD4538BCN https://www.utsource.net/itm/p/12591914.html
Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Supply Voltage | VCC | 3.0 | - | 18.0 | V | |
Operating Temperature | TA | -40 | - | 85 | °C | |
Storage Temperature | TSTG | -65 | - | 150 | °C | |
Input High Voltage | VIH | 2.0 | - | VCC - 1.5 | V | |
Input Low Voltage | VIL | 0.8 | - | 2.0 | V | |
Output High Voltage (Sink) | VOH | - | - | VCC - 0.25 | V | IO = 0.4 mA |
Output Low Voltage (Source) | VOL | 0.1 | - | 0.4 | V | IO = 4.0 mA |
Propagation Delay Time | tpd | - | 170 | 500 | ns | VCC = 5V, fIN = 10 kHz |
Monostable Period | tW | - | - | - | s | tW = R × C, where R is in ohms and C is in farads |
Instructions for Using CD4538BCN
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 3.0V to 18.0V.
- Connect the ground (GND) pin to a stable ground reference.
Input Signals:
- The input high voltage (VIH) should be at least 2.0V but not exceed VCC - 1.5V.
- The input low voltage (VIL) should be between 0.8V and 2.0V.
- Use appropriate pull-up or pull-down resistors if necessary to ensure clean digital signals.
Output Configuration:
- The output high voltage (VOH) will be close to VCC when the output is high.
- The output low voltage (VOL) will be close to 0V when the output is low.
- Ensure the load current does not exceed the maximum ratings for sink and source currents.
Monostable Operation:
- The monostable period (tW) is determined by the external resistor (R) and capacitor (C) connected to the timing pins.
- Calculate tW using the formula tW = R × C, where R is in ohms and C is in farads.
- Choose R and C values to achieve the desired timing period.
Temperature Considerations:
- Operate the device within the temperature range of -40°C to 85°C for reliable performance.
- Store the device in a temperature range of -65°C to 150°C to avoid damage.
Handling Precautions:
- Handle the device with care to avoid static discharge, which can damage the internal circuits.
- Use proper ESD protection measures during handling and installation.
Mounting and Soldering:
- Follow recommended soldering profiles to ensure proper bonding without damaging the device.
- Avoid excessive heat and mechanical stress during mounting.
By following these parameters and instructions, you can ensure the CD4538BCN operates reliably in your application.
(For reference only)View more about CD4538BCN on main site