Details
BUY DG508AAK https://www.utsource.net/itm/p/12591990.html
Parameter | Description | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Supply Voltage | Operating voltage range | 2.7 | - | 5.5 | V |
Off Isolation | Channel-to-channel isolation | - | 60 | - | dB |
On Resistance | Resistance when switch is on | - | 3.8 | - | Ω |
Switching Time | Time to switch between states | - | 10 | - | ns |
Power Dissipation | Maximum power dissipation | - | - | 240 | mW |
Operating Temperature | Temperature range for operation | -40 | - | 85 | °C |
Instructions for DG508AAK:
- Power Supply: Ensure the supply voltage is within the specified range of 2.7V to 5.5V.
- Signal Integrity: For optimal performance, maintain off isolation at around 60dB to prevent signal leakage between channels.
- Resistance Consideration: The on resistance is typically 3.8Ω; design your circuit considering this value to avoid excessive power loss.
- Timing Requirements: The switching time is approximately 10ns, which should be factored into timing-sensitive applications.
- Thermal Management: Do not exceed the maximum power dissipation of 240mW to avoid overheating.
- Environmental Conditions: Operate the device within the temperature range of -40°C to 85°C to ensure reliable performance.
View more about DG508AAK on main site