| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 2.7 | - | 5.5 | V | Supply voltage for the input side |
| Output Voltage | VOUT | - | 5.0 | - | V | Nominal output voltage |
| Isolation Voltage | VIORM | - | - | 5000 | V | Maximum repetitive peak isolation voltage |
| Working Isolation Voltage | VIOWM | - | - | 1140 | V | Continuous working isolation voltage |
| Output Current | IOUT | - | 10 | 20 | mA | Maximum output current |
| Propagation Delay Time | tpd | - | 1.0 | 1.5 | 渭s | Time delay from input to output |
| Rise Time | tr | - | 0.2 | 0.3 | 渭s | Time for output to rise from 10% to 90% |
| Fall Time | tf | - | 0.2 | 0.3 | 渭s | Time for output to fall from 90% to 10% |
| Operating Temperature | TA | -40 | - | 105 | 掳C | Ambient operating temperature range |
| Storage Temperature | TSTG | -55 | - | 150 | 掳C | Temperature range for storage |
| Humidity | RH | - | - | 95 | % | Relative humidity, non-condensing |
| Input Capacitance | CIN | - | 60 | - | pF | Capacitance at input pins |
| Output Capacitance | COUT | - | 10 | - | pF | Capacitance at output pins |
| Common Mode Transient Immunity | CMII | - | 25 | - | kV/渭s | Ability to withstand rapid changes in common mode voltage |
Instructions:
- Supply Voltage (VIN): Ensure the input voltage is within the specified range (2.7V to 5.5V) to avoid damage to the device.
- Output Voltage (VOUT): The nominal output voltage is 5.0V. Use appropriate load resistors to ensure the output current does not exceed the maximum rating.
- Isolation Voltage: The device provides up to 5000V of isolation voltage. Ensure that the working isolation voltage does not exceed 1140V to prevent breakdown.
- Output Current (IOUT): The maximum output current is 20mA. Exceeding this can cause overheating and potential failure.
- Temperature Range: Operate the device within the ambient temperature range of -40掳C to 105掳C and store it between -55掳C and 150掳C.
- Humidity: The device should be used in environments with relative humidity up to 95%, non-condensing.
- Capacitance: Be aware of the input and output capacitance values when designing your circuit to avoid signal distortion.
- Common Mode Transient Immunity (CMII): The device can handle common mode transients up to 25kV/渭s. Design your circuit to minimize such transients if possible.
For detailed application notes and further information, refer to the datasheet provided by the manufacturer.
(For reference only)View more about ACPL-W341-500E on main site