Details
BUY UCC2893DR https://www.utsource.net/itm/p/12593543.html
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | VIN | 10 | - | 40 | V | Operating input voltage range |
Output Voltage | VOUT | - | 5.0 | - | V | Regulated output voltage |
Quiescent Current | IQ | - | 70 | - | μA | Supply current in shutdown mode |
Load Regulation | - | ±2 | - | % | Output voltage change with load | |
Line Regulation | - | ±1 | - | % | Output voltage change with input voltage | |
Start-up Time | TSTART | - | 20 | - | ms | Time to start-up |
Shutdown Current | ISD | - | 10 | - | μA | Current to maintain shutdown state |
Operating Temperature | TOPR | -40 | - | 85 | °C | Operating temperature range |
Storage Temperature | TSTG | -65 | - | 150 | °C | Storage temperature range |
Instructions for UCC2893DR:
Powering the Device:
- Ensure the input voltage is within the specified range of 10V to 40V.
- Connect the input voltage to the designated pin.
Output Configuration:
- The output voltage is regulated to 5.0V nominal. Verify external components like resistors are correctly connected if adjustable output is required.
Thermal Management:
- Operate within the specified temperature range (-40°C to 85°C) for optimal performance.
- Provide adequate heat sinking if operating near maximum temperature limits.
Start-up and Shutdown:
- The device will start up after approximately 20ms once power is applied.
- To enter shutdown mode, apply a current less than 10μA to the shutdown pin.
Load and Line Regulation:
- The device maintains output voltage within ±2% under varying load conditions.
- Line regulation ensures output stability within ±1% across the input voltage range.
Storage Conditions:
- When not in use, store the device between -65°C and 150°C to prevent damage.
Note: Always refer to the specific application notes and detailed datasheet provided by the manufacturer for more precise guidance and additional specifications.
(For reference only)View more about UCC2893DR on main site