Details
BUY RHRP8120 https://www.utsource.net/itm/p/12594160.html
| Parameter | Symbol | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Input Voltage | V_IN | 4.5 | - | 60 | V |
| Output Voltage | V_OUT | 0.8 | - | 55 | V |
| Output Current | I_OUT | - | 20 | 20 | A |
| Efficiency | η | - | 95 | - | % |
| Switching Frequency | f_SW | - | 500 | - | kHz |
| Operating Temperature | T_OP | -40 | - | 125 | °C |
| Storage Temperature | T_STG | -55 | - | 150 | °C |
| Quiescent Current | I_Q | - | 0.2 | - | mA |
| Load Regulation | ΔV_OUT/ΔI_OUT | - | 0.1 | - | mV/A |
| Line Regulation | ΔV_OUT/ΔV_IN | - | 0.01 | - | %/V |
Instructions for Use
Input Voltage (V_IN):
- Ensure the input voltage is within the range of 4.5V to 60V.
- Do not exceed the maximum input voltage to avoid damaging the device.
Output Voltage (V_OUT):
- Set the output voltage using the external feedback resistor network.
- The output voltage can be adjusted from 0.8V to 55V.
Output Current (I_OUT):
- The device can provide a continuous output current of up to 20A.
- Ensure the load does not exceed this limit to prevent overheating or damage.
Efficiency (η):
- The typical efficiency is 95% under normal operating conditions.
- Efficiency may vary depending on the input and output voltages and the load.
Switching Frequency (f_SW):
- The switching frequency is fixed at 500kHz.
- This helps in minimizing the size of external components like inductors and capacitors.
Operating Temperature (T_OP):
- The device can operate in temperatures ranging from -40°C to 125°C.
- Ensure adequate cooling if operating near the upper temperature limit.
Storage Temperature (T_STG):
- Store the device in temperatures ranging from -55°C to 150°C.
- Avoid exposing the device to extreme temperatures for extended periods.
Quiescent Current (I_Q):
- The quiescent current is typically 0.2mA.
- This low current draw helps in reducing power loss when the device is idle.
Load Regulation (ΔV_OUT/ΔI_OUT):
- The load regulation is 0.1mV/A, indicating minimal change in output voltage with varying load currents.
Line Regulation (ΔV_OUT/ΔV_IN):
- The line regulation is 0.01%/V, ensuring stable output voltage even with changes in input voltage.
Additional Notes:
- Always use appropriate decoupling capacitors at the input and output to ensure stable operation.
- Follow the recommended PCB layout guidelines to minimize noise and improve performance.
- For detailed application notes and design considerations, refer to the datasheet provided by the manufacturer.
View more about RHRP8120 on main site