Details
BUY READ2302GSP https://www.utsource.net/itm/p/12594193.html
| Parameter | Description | Value |
|---|---|---|
| Part Number | Device Identifier | READ2302GSP |
| Type | Memory Type | EEPROM |
| Capacity | Storage Capacity | 2 Kbit (256 x 8) |
| Vcc Operating Range | Supply Voltage Range | 1.7V to 5.5V |
| Icc | Current Consumption (Active) | 1 mA max |
| Standby Current | Current Consumption (Standby) | 1 渭A max |
| Operating Temperature | Temperature Range (Operational) | -40掳C to +85掳C |
| Data Retention | Data Retention Time | 100 years |
| Write Cycle | Write Cycles (Endurance) | 1,000,000 |
| Access Time | Read/Write Access Time | 5 渭s max |
| Package | Package Type | SOIC-8 |
| Pins | Number of Pins | 8 |
| Dimensions | Package Dimensions | 5.3 x 4.4 mm |
Instructions for Use
Power Supply:
- Connect Vcc to the positive supply voltage (1.7V to 5.5V).
- Connect GND to the ground.
Pin Configuration:
- Pin 1 (Vcc): Positive supply voltage.
- Pin 2 (GND): Ground.
- Pin 3 (A0): Address input bit 0.
- Pin 4 (A1): Address input bit 1.
- Pin 5 (A2): Address input bit 2.
- Pin 6 (SDA): Serial data line.
- Pin 7 (SCL): Serial clock line.
- Pin 8 (WP): Write protect (active low).
Communication Protocol:
- The READ2302GSP uses I2C protocol for communication.
- SDA and SCL lines must be pulled up with external resistors (typically 4.7k惟 to 10k惟).
Addressing:
- The device has a 7-bit I2C address, which can be configured using the A0, A1, and A2 pins.
- Default address is 0x50 if all address pins are grounded.
Read Operation:
- Start condition on SDA and SCL.
- Send the device address followed by a read bit (R/W = 1).
- Device acknowledges.
- Data bytes are read from the device.
- Stop condition on SDA and SCL.
Write Operation:
- Start condition on SDA and SCL.
- Send the device address followed by a write bit (R/W = 0).
- Device acknowledges.
- Send the memory address where data will be written.
- Device acknowledges.
- Send the data bytes to be written.
- Device acknowledges each byte.
- Stop condition on SDA and SCL.
Write Protect:
- Set WP pin to high to enable write protection.
- Set WP pin to low to allow writing to the device.
Data Retention:
- Data is retained for up to 100 years under specified operating conditions.
Handling:
- Handle the device with care to avoid static damage.
- Ensure proper grounding and power supply stability during operation.
View more about READ2302GSP on main site