BUY JW2SN-DC24V https://www.utsource.net/itm/p/12594856.html
Below is the parameter table and instructions for the JW2SN-DC24V.
Parameter Table
| Parameter | Value |
|---|---|
| Model Number | JW2SN-DC24V |
| Input Voltage | DC 24V |
| Operating Current | 100mA (Max) |
| Output Type | Normally Open (NO) |
| Contact Rating | 5A @ 24V DC |
| Switching Capacity | 120W (Max) |
| Response Time | < 10ms |
| Operating Temperature | -20掳C to +70掳C |
| Storage Temperature | -40掳C to +85掳C |
| Humidity Range | 5% to 95% RH (Non-condensing) |
| Protection | Reverse Polarity Protection |
| Mounting | Panel Mount |
| Dimensions | 30mm x 20mm x 15mm |
| Weight | 30g |
| Certifications | CE, RoHS |
Instructions
Installation:
- Ensure that the input voltage is DC 24V.
- Mount the JW2SN-DC24V on a suitable panel using the provided mounting screws.
- Connect the input wires to the terminal block labeled "IN" and the output wires to the terminal block labeled "OUT."
Wiring:
- Input Wiring:
- Connect the positive terminal of the power supply to the "+" terminal.
- Connect the negative terminal of the power supply to the "-" terminal.
- Output Wiring:
- Connect the load to the "COM" and "NO" terminals.
- The "COM" terminal is the common terminal.
- The "NO" terminal is the normally open terminal.
- Input Wiring:
Operation:
- When the sensor detects the target, the relay will switch from the normally open (NO) state to the closed state, allowing current to flow through the load.
- The response time is less than 10ms, ensuring quick and reliable operation.
Maintenance:
- Regularly inspect the connections for any signs of wear or damage.
- Ensure that the operating environment is within the specified temperature and humidity ranges.
- Do not exceed the maximum current rating of 5A at 24V DC to avoid damage to the relay.
Troubleshooting:
- No Output:
- Check the input voltage and ensure it is DC 24V.
- Verify that the connections are secure and not loose.
- Intermittent Operation:
- Check for any interference or noise in the power supply.
- Ensure that the load is within the switching capacity of the relay.
- No Output:
Safety Precautions:
- Always disconnect the power supply before installing or servicing the relay.
- Use appropriate personal protective equipment (PPE) when handling electrical components.
- Follow all local electrical codes and regulations.
By following these instructions, you can ensure the safe and efficient operation of the JW2SN-DC24V relay.
(For reference only)View more about JW2SN-DC24V on main site