Details
BUY TOP247YN https://www.utsource.net/itm/p/12595074.html
| Parameter | Symbol | Min | Typ | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 85 | - | 265 | VAC | Operating input voltage range |
| Output Voltage | VOUT | - | 5 | - | VDC | Typical output voltage (can be adjusted) |
| Output Current | IOUT | - | 1.5 | - | A | Maximum continuous output current |
| Efficiency | 畏 | - | 85 | - | % | Typical efficiency at full load |
| Power Factor | PF | - | 0.9 | - | - | Typical power factor at full load |
| No-Load Power | PNL | - | 0.15 | - | W | Typical no-load power consumption |
| Switching Frequency | fSW | 70 | - | 132 | kHz | Switching frequency range |
| Isolation Voltage | VISSO | - | 3000 | - | VAC | Input to output isolation voltage (1 minute, 50/60 Hz) |
| Operating Temperature | Toper | -40 | - | 85 | 掳C | Operating temperature range |
| Storage Temperature | Tstg | -40 | - | 125 | 掳C | Storage temperature range |
| Humidity | RH | - | 85 | - | % | Relative humidity, non-condensing |
| Inrush Current | IINRUSH | - | 20 | - | A | Peak inrush current |
| EMI Filter | - | - | - | - | - | Integrated EMI filter for compliance with EN55022 Class B |
Instructions for Using TOP247YN
Input Connection:
- Connect the AC input to the designated input terminals of the TOP247YN.
- Ensure the input voltage is within the specified range (85VAC to 265VAC).
Output Connection:
- Connect the load to the output terminals of the TOP247YN.
- Verify that the load does not exceed the maximum output current (1.5A).
Mounting:
- Mount the TOP247YN on a suitable heatsink to ensure proper heat dissipation.
- Ensure adequate airflow around the device to maintain operating temperatures within the specified range.
Power-On Sequence:
- Apply the input voltage gradually to avoid inrush current surges.
- Monitor the output voltage and current to ensure stable operation.
Safety Precautions:
- Do not operate the device in environments exceeding the specified temperature and humidity ranges.
- Ensure proper insulation and grounding to prevent electrical shock.
Testing and Troubleshooting:
- Use a multimeter to verify the output voltage and current.
- If the device fails to start or operates abnormally, check the input voltage, connections, and load.
Compliance:
- The TOP247YN is designed to comply with EN55022 Class B for electromagnetic interference (EMI).
- Ensure all external components and wiring meet the required standards.
Storage:
- Store the device in a dry, cool place away from direct sunlight and extreme temperatures.
- Avoid exposure to corrosive substances and mechanical stress during storage.
View more about TOP247YN on main site