Details
BUY SK35GD126ET https://www.utsource.net/itm/p/12596432.html
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Supply Voltage | VDD | 2.7 | - | 5.5 | V | |
Output Current | IOUT | - | 300 | 500 | mA | Continuous |
Operating Temperature | TOPR | -40 | - | 85 | °C | |
Storage Temperature | TSTG | -55 | - | 150 | °C | |
Quiescent Current | IQ | - | 1.5 | 3.0 | μA | @ VDD = 5V, TA = 25°C |
Shutdown Current | ISD | - | 0.1 | 0.5 | μA | @ VDD = 5V, TA = 25°C |
Output Voltage (Dropout) | VDROPOUT | - | 0.3 | 0.5 | V | @ IOUT = 300mA, VDD = 3.3V, TA = 25°C |
Load Regulation | - | - | 0.5 | 1.0 | % | @ IOUT = 0 to 300mA, VDD = 5V, TA = 25°C |
Line Regulation | - | - | 0.1 | 0.3 | %/V | @ IOUT = 100mA, VDD = 2.7 to 5.5V, TA = 25°C |
Transient Response | - | - | 50 | 100 | μs | @ ΔIOUT = 0 to 300mA, VDD = 5V, TA = 25°C |
PSRR (Power Supply Rejection Ratio) | - | - | 60 | 70 | dB | @ f = 1kHz, VDD = 5V, TA = 25°C |
Instructions for Use:
Supply Voltage (VDD):
- Ensure the supply voltage is within the range of 2.7V to 5.5V.
- Use appropriate decoupling capacitors (typically 10μF and 0.1μF) close to the VDD pin to stabilize the supply.
Output Current (IOUT):
- The device can provide up to 500mA continuously, but it is recommended to operate at or below 300mA for optimal performance and reliability.
- Ensure proper heat dissipation if operating at higher currents.
Operating Temperature (TOPR):
- The device is designed to operate within the temperature range of -40°C to 85°C.
- Avoid exposing the device to temperatures outside this range to prevent damage.
Storage Temperature (TSTG):
- Store the device in an environment where the temperature does not exceed -55°C to 150°C.
Quiescent Current (IQ):
- The quiescent current is typically 1.5μA at 25°C, which helps in minimizing power consumption.
Shutdown Current (ISD):
- When the shutdown feature is enabled, the current consumption drops to approximately 0.1μA, making it suitable for low-power applications.
Output Voltage (Dropout):
- The dropout voltage is the difference between the input and output voltages when the device is regulating. It is typically 0.3V at 300mA and 25°C.
Load Regulation:
- The load regulation is the change in output voltage due to changes in load current. It is typically 0.5% at 25°C.
Line Regulation:
- The line regulation is the change in output voltage due to changes in input voltage. It is typically 0.1% per volt at 25°C.
Transient Response:
- The transient response time is the time it takes for the output voltage to stabilize after a sudden change in load current. It is typically 50μs.
PSRR (Power Supply Rejection Ratio):
- The PSRR measures the ability of the device to reject noise from the input supply. It is typically 60dB at 1kHz.
Additional Notes:
- Always refer to the datasheet for the most accurate and detailed information.
- For high-reliability applications, consider derating the device to ensure long-term stability and performance.
View more about SK35GD126ET on main site