Parameter Symbol Min Typ Max Unit Description
Supply Voltage Vcc 4.5 5.0 5.5 V Operating voltage range
Supply Current (Active) Icc - 15 - mA Typical supply current in active mode
Supply Current (Standby) Isb - 1 - μA Typical supply current in standby mode
Operating Temperature Topr -40 - 85 °C Operating temperature range
Storage Temperature Tstg -65 - 150 °C Storage temperature range
Output Current per Segment Iseg - 25 - mA Maximum output current per segment
Character Height Hc - 14 - mm Typical character height for 7-segment displays
Digit Count N 4 - - - Number of digits supported
Refresh Rate fref - 300 - Hz Typical refresh rate for multiplexed displays
Duty Cycle D 1/2 - 1/8 - Supported duty cycles
Baud Rate Baud - 9600 - bps Typical baud rate for serial communication

Instructions for Using the ICM7217BIPI

  1. Power Supply:

    • Connect the Vcc pin to a 4.5V to 5.5V power supply.
    • Connect the GND pin to the ground.
  2. Serial Communication:

    • Use the serial input (SI) pin to send data to the ICM7217BIPI.
    • Set the baud rate to 9600 bps for typical operation.
    • Use the clock (SCK) pin to synchronize data transmission.
    • The enable (E) pin should be pulled low to enable data reception.
  3. Display Configuration:

    • Configure the display parameters such as digit count, duty cycle, and character height using the appropriate commands.
    • Set the brightness level by adjusting the output current per segment (Iseg).
  4. Data Transmission:

    • Send data in the form of 8-bit commands or data bytes.
    • Each command or data byte should be followed by a clock pulse on the SCK pin.
  5. Multiplexing:

    • For multiplexed displays, set the duty cycle according to the number of digits.
    • Ensure the refresh rate is at least 300 Hz to avoid flickering.
  6. Standby Mode:

    • To enter standby mode, pull the enable (E) pin high.
    • In standby mode, the supply current is reduced to approximately 1 μA.
  7. Reset:

    • A reset can be performed by pulling the reset (RST) pin low for at least 100 μs and then releasing it.
  8. Error Handling:

    • Monitor the status pins for any errors or faults during operation.
    • Implement error handling routines to manage any issues that arise.

By following these instructions, you can effectively use the ICM7217BIPI to control and drive 7-segment displays with ease.