| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | Operating | 4.5 | - | 5.5 | V |
| Output Voltage | VOUT | No Load | - | 16 | - | V |
| Quiescent Current | IQ | VDD = 5V | - | 200 | - | 渭A |
| Output Current | IOUT | Continuous Operation | - | 50 | - | mA |
| Thermal Shutdown | TSD | Active | - | 160 | - | 掳C |
| Protection | Overcurrent, Short | - | - | - | - | |
| Operating Temperature | TOPR | Storage | -40 | - | 85 | 掳C |
Instructions for HV101M016E055ETR:
Power Supply Connection:
- Connect the supply voltage (VDD) between 4.5V and 5.5V to ensure stable operation.
Output Configuration:
- The output voltage (VOUT) is set to 16V under no load conditions. Ensure that the load does not exceed the maximum continuous output current of 50mA.
Thermal Management:
- Monitor the operating temperature to avoid exceeding 160掳C, which triggers thermal shutdown. Use adequate heat dissipation methods if necessary.
Protection Features:
- The device includes overcurrent and short-circuit protection. Do not bypass these features as they are crucial for safe operation.
Environmental Conditions:
- Store and operate the device within the temperature range of -40掳C to 85掳C to maintain reliability and performance.
Quiescent Current:
- Keep in mind the quiescent current of 200渭A at a supply voltage of 5V when considering power consumption in low-power applications.