Details
BUY TLP700H(TP,F) https://www.utsource.net/itm/p/12597208.html
Parameter | Symbol | Min | Typ. | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Forward Voltage | VF | 1.0 | 1.2 | 1.4 | V | IF = 50 mA |
Reverse Breakdown Voltage | VR | - | 5.0 | - | V | IR = 1 mA |
Forward Current | IF | - | 50 | - | mA | VF = 1.2 V |
Output Current | IO | - | 30 | - | mA | VO = 4.5 V |
Isolation Voltage | VIORM | - | 2500 | - | Vrms | 1 min, 50/60 Hz |
Insulation Resistance | RISO | 500 | - | - | MΩ | VIF = 500 Vdc |
Propagation Delay Time | tPLH | 10 | 18 | 26 | μs | IF = 50 mA, IO = 30 mA |
Storage Temperature | TSTG | -40 | - | 105 | °C | - |
Operating Temperature | TOPR | -40 | - | 85 | °C | - |
Instructions for TLP700H(TP,F)
Mounting and Handling:
- Handle with care to avoid damage.
- Ensure proper heat sinking if operating at high currents.
Electrical Connections:
- Connect the forward current (IF) leads correctly to avoid reverse polarity which can damage the device.
- Ensure that the output current (IO) does not exceed the maximum rating of 30 mA to prevent overheating.
Insulation and Safety:
- Maintain a minimum isolation voltage of 2500 Vrms for safety and performance.
- Regularly check insulation resistance to ensure it meets or exceeds 500 MΩ.
Temperature Considerations:
- Operate within the specified temperature range (-40°C to 85°C) for optimal performance.
- Store in environments between -40°C and 105°C to avoid degradation.
Timing and Delays:
- Account for propagation delay times (tPLH) when designing circuits to ensure accurate timing.
Testing:
- When testing, apply voltages and currents within specified limits to avoid damaging the component.
- Use appropriate test equipment calibrated to measure small currents and voltages accurately.
View more about TLP700H(TP,F) on main site