CD4066BE

CD4066BE


Specifications
SKU
12597231
Details

BUY CD4066BE https://www.utsource.net/itm/p/12597231.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VDD - 3 15 - V
Supply Current (Quiescent) IDD VDD = 15V, all switches off - 1 - 渭A
Input High Voltage VIH - 2.0 3.5 VDD V
Input Low Voltage VIL - 0 1.5 - V
Output High Voltage VOH IO = -1mA - VDD - 0.1 VDD - 0.5 V
Output Low Voltage VOL IO = 1mA 0.1 0.5 - V
On-State Resistance RON VDD = 15V, VIN = VDD/2, IO = 卤10mA - 125 250
Off-State Leakage Current IOFF VDD = 15V, VIN = 0V or VDD - - 1 nA
Switching Time (Typical) tpd VDD = 15V, VIN = 0V to VDD - 15 - ns

Instructions for Using CD4066BE

  1. Supply Voltage:

    • Ensure the supply voltage (VDD) is within the range of 3V to 15V.
    • Connect VDD to the positive supply and GND to the ground.
  2. Input Levels:

    • For a high input (VIH), the voltage should be at least 2.0V and can go up to VDD.
    • For a low input (VIL), the voltage should be between 0V and 1.5V.
  3. Output Levels:

    • When a switch is on, the output high voltage (VOH) will be close to VDD minus a small drop (0.1V to 0.5V).
    • When a switch is off, the output low voltage (VOL) will be close to 0V with a small rise (0.1V to 0.5V).
  4. On-State Resistance:

    • The resistance when the switch is on (RON) is typically around 125惟 but can vary between 125惟 and 250惟 depending on conditions.
  5. Off-State Leakage Current:

    • The leakage current when the switch is off (IOFF) is very low, typically less than 1nA.
  6. Switching Time:

    • The typical propagation delay time (tpd) is 15ns, which is the time it takes for the output to change state after the input changes.
  7. Handling and Storage:

    • Handle the device with care to avoid damage from static electricity.
    • Store in a dry environment to prevent moisture damage.
  8. Layout Considerations:

    • Keep signal paths short to minimize noise and interference.
    • Use decoupling capacitors (e.g., 0.1渭F) close to the power pins to filter out noise.
  9. Testing:

    • Test the device under typical operating conditions to ensure it meets the specified parameters.
    • Verify the switching behavior and leakage currents to ensure proper functionality.

By following these guidelines, you can effectively use the CD4066BE in your circuits.

(For reference only)

View more about CD4066BE on main site