MAX485CPA

MAX485CPA


Specifications
SKU
12597595
Details

BUY MAX485CPA https://www.utsource.net/itm/p/12597595.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating 4.75 - 5.25 V
Supply Current (Receive Mode) ICC(R) VCC = 5V, No Load - 300 - μA
Supply Current (Transmit Mode) ICC(T) VCC = 5V, No Load - 400 - μA
Driver Output High-Level Voltage VODH VCC = 5V, IOL = 100mA 2.0 - 5.0 V
Driver Output Low-Level Voltage VODL VCC = 5V, IOH = -100mA 0.2 - 0.6 V
Receiver Input High-Level Voltage VRH - 2.0 - 5.0 V
Receiver Input Low-Level Voltage VRL - 0.0 - 0.8 V
Receiver Output High-Level Voltage VOH VCC = 5V, IOL = 0.4mA 2.4 - 5.0 V
Receiver Output Low-Level Voltage VOL VCC = 5V, IOH = -4.0mA 0.4 - 0.5 V
Differential Input Voltage Range VID - - - 12 V
Common-Mode Input Voltage Range VICM - -2 - 7 V
Driver Rise Time trD VCC = 5V, CL = 50pF - 30 - ns
Driver Fall Time tfD VCC = 5V, CL = 50pF - 30 - ns
Receiver Propagation Delay tpdR VCC = 5V, VID = 200mV - 350 - ns
Receiver Maximum Data Rate fmax VCC = 5V - - 2.5 Mbps

Instructions for Using the MAX485CPA:

  1. Power Supply:

    • Connect the VCC pin to a 5V power supply.
    • Connect the GND pin to the ground.
  2. Data Transmission:

    • Connect the DI (Data Input) pin to the microcontroller or other data source.
    • Connect the DE (Driver Enable) pin to a control signal to enable transmission.
    • Connect the RO (Receiver Output) pin to the microcontroller or other data destination.
    • Connect the RE (Receiver Enable) pin to a control signal to enable reception.
  3. Differential Bus Connections:

    • Connect the A and B pins to the differential bus lines.
    • Ensure that the bus lines are properly terminated with a 120Ω resistor at each end to prevent reflections and ensure reliable communication.
  4. Configuration:

    • To transmit data, set DE high and RE low.
    • To receive data, set DE low and RE high.
    • For half-duplex operation, connect DE and RE together and control them with a single signal.
  5. Signal Levels:

    • Ensure that the differential input voltage (VID) is within the specified range (-12V to +12V).
    • Ensure that the common-mode input voltage (VICM) is within the specified range (-2V to +7V).
  6. Timing:

    • The receiver propagation delay (tpdR) should be considered when designing the timing of your system.
    • The maximum data rate (fmax) is 2.5 Mbps, so ensure that your system can handle this speed.
  7. Supply Current:

    • Monitor the supply current (ICC(R) and ICC(T)) to ensure it does not exceed the typical values during operation.
  8. Environmental Considerations:

    • The device is designed for industrial environments and can operate over a wide temperature range (-40°C to +85°C).

By following these instructions and parameters, you can effectively integrate the MAX485CPA into your RS-485 communication system.

(For reference only)

View more about MAX485CPA on main site