Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VCC | Operating | 4.75 | - | 5.25 | V |
Supply Current (Receive Mode) | ICC(R) | VCC = 5V, No Load | - | 300 | - | μA |
Supply Current (Transmit Mode) | ICC(T) | VCC = 5V, No Load | - | 400 | - | μA |
Driver Output High-Level Voltage | VODH | VCC = 5V, IOL = 100mA | 2.0 | - | 5.0 | V |
Driver Output Low-Level Voltage | VODL | VCC = 5V, IOH = -100mA | 0.2 | - | 0.6 | V |
Receiver Input High-Level Voltage | VRH | - | 2.0 | - | 5.0 | V |
Receiver Input Low-Level Voltage | VRL | - | 0.0 | - | 0.8 | V |
Receiver Output High-Level Voltage | VOH | VCC = 5V, IOL = 0.4mA | 2.4 | - | 5.0 | V |
Receiver Output Low-Level Voltage | VOL | VCC = 5V, IOH = -4.0mA | 0.4 | - | 0.5 | V |
Differential Input Voltage Range | VID | - | - | - | 12 | V |
Common-Mode Input Voltage Range | VICM | - | -2 | - | 7 | V |
Driver Rise Time | trD | VCC = 5V, CL = 50pF | - | 30 | - | ns |
Driver Fall Time | tfD | VCC = 5V, CL = 50pF | - | 30 | - | ns |
Receiver Propagation Delay | tpdR | VCC = 5V, VID = 200mV | - | 350 | - | ns |
Receiver Maximum Data Rate | fmax | VCC = 5V | - | - | 2.5 | Mbps |
Instructions for Using the MAX485CPA:
Power Supply:
- Connect the VCC pin to a 5V power supply.
- Connect the GND pin to the ground.
Data Transmission:
- Connect the DI (Data Input) pin to the microcontroller or other data source.
- Connect the DE (Driver Enable) pin to a control signal to enable transmission.
- Connect the RO (Receiver Output) pin to the microcontroller or other data destination.
- Connect the RE (Receiver Enable) pin to a control signal to enable reception.
Differential Bus Connections:
- Connect the A and B pins to the differential bus lines.
- Ensure that the bus lines are properly terminated with a 120Ω resistor at each end to prevent reflections and ensure reliable communication.
Configuration:
- To transmit data, set DE high and RE low.
- To receive data, set DE low and RE high.
- For half-duplex operation, connect DE and RE together and control them with a single signal.
Signal Levels:
- Ensure that the differential input voltage (VID) is within the specified range (-12V to +12V).
- Ensure that the common-mode input voltage (VICM) is within the specified range (-2V to +7V).
Timing:
- The receiver propagation delay (tpdR) should be considered when designing the timing of your system.
- The maximum data rate (fmax) is 2.5 Mbps, so ensure that your system can handle this speed.
Supply Current:
- Monitor the supply current (ICC(R) and ICC(T)) to ensure it does not exceed the typical values during operation.
Environmental Considerations:
- The device is designed for industrial environments and can operate over a wide temperature range (-40°C to +85°C).
By following these instructions and parameters, you can effectively integrate the MAX485CPA into your RS-485 communication system.