NY24W-K

NY24W-K


Specifications
SKU
12597895
Details

BUY NY24W-K https://www.utsource.net/itm/p/12597895.html

Parameter Description Value
Part Number Identification of the component NY24W-K
Type Type of component Photocoupler
Isolation Voltage Maximum isolation voltage between input and output 5000 Vrms
Forward Current Maximum forward current through the LED 60 mA
Peak Forward Current Maximum peak forward current through the LED (10 渭s pulse) 1 A
Forward Voltage Typical forward voltage drop across the LED 1.2 V (max 1.6 V) at IF = 20 mA
Reverse Voltage Maximum reverse voltage across the LED 5 V
Output Current Maximum collector current of the phototransistor 50 mA
Collector-Emitter Voltage Maximum voltage between collector and emitter 70 V
Storage Temperature Temperature range for storage -40掳C to +100掳C
Operating Temperature Temperature range for operation -40掳C to +85掳C
Response Time Time required for the output to switch (Typical) 2 渭s (ton), 1 渭s (toff)
CTR (Current Transfer Ratio) Ratio of output current to input current (min) 20% at IF = 5 mA, VCE = 5 V

Instructions for Use

  1. Mounting:

    • Ensure that the component is mounted on a PCB with proper spacing to avoid short circuits.
    • Follow the recommended footprint and soldering guidelines provided by the manufacturer.
  2. Power Supply:

    • The input side (LED) should be driven with a current-limited power supply to prevent damage from excessive current.
    • The output side (phototransistor) should be connected to a suitable load and power supply within the specified voltage and current limits.
  3. Handling:

    • Handle the component with care to avoid mechanical stress or damage.
    • Use appropriate ESD protection measures when handling the component to prevent electrostatic discharge damage.
  4. Testing:

    • Test the component using a signal generator and an oscilloscope to verify its performance parameters.
    • Ensure that the test conditions match the specifications provided in the datasheet.
  5. Storage:

    • Store the component in a dry, cool place within the specified temperature range to maintain its performance and reliability.
  6. Operational Conditions:

    • Operate the component within the specified temperature and voltage ranges to ensure reliable performance.
    • Avoid subjecting the component to prolonged exposure to extreme temperatures or voltages.
  7. Safety:

    • Ensure that the isolation voltage rating is not exceeded to prevent electrical hazards.
    • Follow all safety guidelines and regulations when designing and operating circuits that include this component.
(For reference only)

View more about NY24W-K on main site