Details
BUY NY24W-K https://www.utsource.net/itm/p/12597895.html
| Parameter | Description | Value |
|---|---|---|
| Part Number | Identification of the component | NY24W-K |
| Type | Type of component | Photocoupler |
| Isolation Voltage | Maximum isolation voltage between input and output | 5000 Vrms |
| Forward Current | Maximum forward current through the LED | 60 mA |
| Peak Forward Current | Maximum peak forward current through the LED (10 渭s pulse) | 1 A |
| Forward Voltage | Typical forward voltage drop across the LED | 1.2 V (max 1.6 V) at IF = 20 mA |
| Reverse Voltage | Maximum reverse voltage across the LED | 5 V |
| Output Current | Maximum collector current of the phototransistor | 50 mA |
| Collector-Emitter Voltage | Maximum voltage between collector and emitter | 70 V |
| Storage Temperature | Temperature range for storage | -40掳C to +100掳C |
| Operating Temperature | Temperature range for operation | -40掳C to +85掳C |
| Response Time | Time required for the output to switch (Typical) | 2 渭s (ton), 1 渭s (toff) |
| CTR (Current Transfer Ratio) | Ratio of output current to input current (min) | 20% at IF = 5 mA, VCE = 5 V |
Instructions for Use
Mounting:
- Ensure that the component is mounted on a PCB with proper spacing to avoid short circuits.
- Follow the recommended footprint and soldering guidelines provided by the manufacturer.
Power Supply:
- The input side (LED) should be driven with a current-limited power supply to prevent damage from excessive current.
- The output side (phototransistor) should be connected to a suitable load and power supply within the specified voltage and current limits.
Handling:
- Handle the component with care to avoid mechanical stress or damage.
- Use appropriate ESD protection measures when handling the component to prevent electrostatic discharge damage.
Testing:
- Test the component using a signal generator and an oscilloscope to verify its performance parameters.
- Ensure that the test conditions match the specifications provided in the datasheet.
Storage:
- Store the component in a dry, cool place within the specified temperature range to maintain its performance and reliability.
Operational Conditions:
- Operate the component within the specified temperature and voltage ranges to ensure reliable performance.
- Avoid subjecting the component to prolonged exposure to extreme temperatures or voltages.
Safety:
- Ensure that the isolation voltage rating is not exceeded to prevent electrical hazards.
- Follow all safety guidelines and regulations when designing and operating circuits that include this component.
View more about NY24W-K on main site