LM393

LM393


Specifications
SKU
12598120
Details

BUY LM393 https://www.utsource.net/itm/p/12598120.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage Vcc Operating 2.0 5.0 36 V
Supply Current ICC All inputs low - 100 - 渭A
Input Offset Voltage Vos VI = 0V - 2 7 mV
Input Bias Current IB VI = 0V - 25 250 nA
Input Voltage Range VI 0 - Vcc V
Output Low Voltage VOL IO = 10mA, Vcc = 5V 0.1 - 0.4 V
Output High Voltage VOH IO = -100渭A, Vcc = 5V 4.5 - 5.0 V
Output Sink Current IOL VOL = 0.4V 16 - 50 mA
Output Source Current IOH VOH = 4.5V 0.5 - 1.6 mA
Propagation Delay Time tpd VI to VO, Vcc = 5V - 250 - ns
Storage Temperature Range Tstg -65 - 150 掳C
Operating Temperature Range Topr -40 - 85 掳C

Instructions for Using the LM393:

  1. Power Supply:

    • The LM393 can operate with a supply voltage ranging from 2.0V to 36V.
    • Ensure the supply voltage is stable and within the specified range to avoid damage to the device.
  2. Input Connections:

    • Connect the input signals to the non-inverting (pin 2) and inverting (pin 3) inputs of the comparator.
    • The input voltage range should be between 0V and the supply voltage (Vcc).
  3. Output Connections:

    • The output of the comparator is open-collector, which means it can sink current but not source it.
    • Use a pull-up resistor to the supply voltage (Vcc) to ensure a high output level when the comparator is not active.
    • The typical value for the pull-up resistor is between 1k惟 and 10k惟.
  4. Supply Current:

    • The typical supply current is 100渭A when all inputs are low.
    • Ensure that the power supply can provide sufficient current to meet this requirement.
  5. Temperature Considerations:

    • The operating temperature range is from -40掳C to 85掳C.
    • The storage temperature range is from -65掳C to 150掳C.
    • Avoid exposing the device to temperatures outside these ranges to prevent damage.
  6. Propagation Delay:

    • The propagation delay time is typically 250ns at a supply voltage of 5V.
    • This is the time it takes for the output to change state after the input changes.
  7. Handling and Storage:

    • Handle the LM393 with care to avoid static damage.
    • Store the device in a dry, cool place within the specified storage temperature range.

By following these instructions, you can ensure reliable operation of the LM393 comparator in your circuit.

(For reference only)

View more about LM393 on main site