AR1021-I/SS
Specifications
SKU
12598150
Details
BUY AR1021-I/SS https://www.utsource.net/itm/p/12598150.html
Parameter | Description | Value |
---|---|---|
Part Number | Full part number | AR1021-I/SS |
Type | Device type | Hall Effect Sensor |
Supply Voltage (VCC) | Operating supply voltage range | 4.5 V to 5.5 V |
Output Type | Output configuration | Digital Open Collector |
Quiescent Supply Current (ICC) | Supply current at no load | 8 mA (max) |
Output Low Voltage (VOL) | Maximum output low voltage under load | 0.4 V (max) |
Magnetic Sensitivity (BOP) | Magnetic field strength to turn on | 25 Gauss (typ) |
Release Point (BRP) | Magnetic field strength to turn off | -25 Gauss (typ) |
Hysteresis (BHYS) | Difference between BOP and BRP | 50 Gauss (typ) |
Operating Temperature Range (Toper) | Temperature range for operation | -40°C to 85°C |
Storage Temperature Range (Tstg) | Temperature range for storage | -40°C to 150°C |
Package Type | Encapsulation or package style | SOT-23 |
Lead Finish | Surface finish of leads | SnPb (60/40) |
RoHS Compliance | Compliance with RoHS directive | Yes |
Instructions:
Power Supply:
- Connect the VCC pin to a stable power supply within the specified range (4.5 V to 5.5 V).
- Connect the GND pin to the ground.
Output Connection:
- Connect the OUT pin to a pull-up resistor (typically 1 kΩ to 10 kΩ) to the supply voltage.
- The output will be low (0.4 V max) when the magnetic field exceeds the BOP threshold and high (open collector) otherwise.
Magnetic Field Application:
- Place the sensor in a position where the magnetic field from a magnet or other source can be detected.
- Ensure the magnetic field strength is within the operational range to trigger the sensor.
Temperature Considerations:
- Operate the sensor within the specified temperature range (-40°C to 85°C) for optimal performance.
- Store the sensor in a dry environment within the storage temperature range (-40°C to 150°C).
Handling:
- Handle the sensor with care to avoid damage to the leads or the package.
- Follow ESD (Electrostatic Discharge) precautions to prevent damage to the device.
Testing:
- Test the sensor by applying a known magnetic field and verifying the output state using a multimeter or oscilloscope.
Mounting:
- Mount the sensor on a PCB using standard SMT (Surface Mount Technology) techniques.
- Ensure proper soldering and alignment during assembly.
View more about AR1021-I/SS on main site