Details
BUY HED52XXU11 https://www.utsource.net/itm/p/12598229.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | 4.5 | 5.0 | 5.5 | V | Operating supply voltage |
| Supply Current | Icc | - | 10 | 20 | mA | Quiescent current |
| Output Type | - | - | - | - | Open-collector | Output configuration |
| Maximum Output Current | Iout | - | - | 20 | mA | Maximum current through output |
| Maximum Power Dissipation | Pd | - | - | 150 | mW | Maximum power dissipation |
| Operating Temperature | Topr | -40 | - | 85 | 掳C | Operating temperature range |
| Storage Temperature | Tstg | -65 | - | 150 | 掳C | Storage temperature range |
| Response Time | tr | - | 10 | 30 | 渭s | Time to switch from off to on |
| Release Time | tf | - | 10 | 30 | 渭s | Time to switch from on to off |
| Maximum Load Inductance | Lmax | - | - | 30 | mH | Maximum load inductance |
| Maximum Load Capacitance | Cmax | - | - | 10 | 渭F | Maximum load capacitance |
Instructions for Use:
Supply Voltage (Vcc):
- Ensure the supply voltage is within the specified range (4.5V to 5.5V) to avoid damage to the device.
Supply Current (Icc):
- The quiescent current should not exceed 20mA to prevent overheating.
Output Configuration:
- The output is open-collector, requiring an external pull-up resistor to the desired logic level.
Maximum Output Current (Iout):
- Do not exceed 20mA through the output to avoid damaging the device.
Maximum Power Dissipation (Pd):
- Ensure the power dissipation does not exceed 150mW to maintain reliable operation.
Operating Temperature (Topr):
- Operate the device within the temperature range of -40掳C to 85掳C to ensure proper functionality.
Storage Temperature (Tstg):
- Store the device in an environment with temperatures ranging from -65掳C to 150掳C.
Response Time (tr) and Release Time (tf):
- The device will switch from off to on within 10 to 30渭s and from on to off within the same range.
Maximum Load Inductance (Lmax) and Maximum Load Capacitance (Cmax):
- Ensure the load inductance does not exceed 30mH and the load capacitance does not exceed 10渭F to prevent issues with switching performance.
View more about HED52XXU11 on main site