Details
BUY FNB51560TD1 https://www.utsource.net/itm/p/12598252.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | Operating Range | 4.5 | - | 60 | V |
| Output Voltage | VOUT | Adjustable Range | 0.8 | - | 20 | V |
| Switching Frequency | fSW | Default Setting | - | 600 | - | kHz |
| Output Current | IOUT | Continuous | - | 5 | 6 | A |
| Efficiency | η | @VOUT=12V, IOUT=3A | - | 92 | - | % |
| Quiescent Current | IQ | No Load | - | 60 | - | μA |
| Shutdown Current | ISD | VEN=0V | - | 1 | - | μA |
| Thermal Shutdown | TSD | Activation | - | 160 | - | °C |
| Package Type | - | - | - | - | - | SOIC-8 |
Instructions for FNB51560TD1
Power Supply Connection:
- Connect the input voltage (VIN) within the operating range of 4.5V to 60V.
- Ensure proper bypassing with a ceramic capacitor close to the VIN pin.
Output Configuration:
- Set the output voltage (VOUT) using external resistors as per the datasheet formula.
- The adjustable range is from 0.8V to 20V.
Frequency Adjustment:
- The default switching frequency is set at 600kHz. For different applications, adjust via an external resistor if needed.
Thermal Considerations:
- Monitor the thermal shutdown threshold of 160°C and ensure adequate heat dissipation.
Enable Pin:
- Use the enable pin (VEN) to control the on/off state of the regulator.
- When VEN is pulled low (<0.4V), the device enters shutdown mode drawing ≤1μA.
Protection Features:
- The device includes overcurrent and thermal protection features to safeguard against fault conditions.
Layout Recommendations:
- Place the input and output capacitors as close as possible to the IC to minimize noise and improve stability.
- Follow recommended PCB layout guidelines provided in the datasheet for optimal performance.
For detailed specifications and further information, refer to the official datasheet of FNB51560TD1.
(For reference only)View more about FNB51560TD1 on main site