Details
BUY ACS722LLCTR-40AB-T https://www.utsource.net/itm/p/12598430.html
Below is the parameter table and instructions for the ACS722LLCTR-40AB-T, which is a Hall Effect-Based Linear Current Sensor IC from Allegro MicroSystems.
ACS722LLCTR-40AB-T Parameter Table
| Parameter | Symbol | Min | Typical | Max | Unit |
|---|---|---|---|---|---|
| Supply Voltage | VCC | 4.5 | 5.0 | 5.5 | V |
| Quiescent Output Voltage | VQ | 2.4 | 2.5 | 2.6 | V |
| Output Sensitivity | SV | 10.5 | 13.3 | 16.1 | mV/A |
| Output Impedance | ROUT | - | 15 | - | 惟 |
| Bandwidth | fBW | - | 80 | - | kHz |
| Maximum Continuous Current | IMAX | - | 40 | - | A |
| Maximum Overcurrent | IPEAK | - | 80 | - | A (1 ms) |
| Operating Temperature Range | TA | -40 | - | 150 | 掳C |
| Storage Temperature Range | TSTG | -65 | - | 150 | 掳C |
| Lead Temperature (Soldering) | TL | - | - | 260 | 掳C (10 s) |
Instructions for Use
Power Supply:
- The ACS722LLCTR-40AB-T requires a stable 5V supply voltage. Ensure that the power supply is within the specified range (4.5V to 5.5V) to avoid damage to the device.
- Use a decoupling capacitor (e.g., 100nF) close to the VCC and GND pins to filter out noise and ensure stable operation.
Current Sensing:
- The current to be measured should pass through the primary conductor, which is the center pin (Pin 1) of the device.
- The maximum continuous current that can be sensed is 40A. For short durations (up to 1 ms), the device can handle up to 80A.
Output Signal:
- The output voltage (VOUT) is proportional to the current flowing through the primary conductor.
- The quiescent output voltage (VQ) is typically 2.5V when no current is flowing.
- The sensitivity of the output voltage to current is typically 13.3 mV/A. For example, if 10A is flowing through the primary conductor, the output voltage will be approximately 2.5V + (10A * 13.3 mV/A) = 2.633V.
Temperature Considerations:
- The operating temperature range is from -40掳C to 150掳C. Ensure that the device is not exposed to temperatures outside this range to prevent damage.
- The storage temperature range is from -65掳C to 150掳C.
Handling and Installation:
- Handle the device with care to avoid static discharge, which can damage the internal circuitry.
- When soldering, do not exceed the lead temperature of 260掳C for more than 10 seconds to avoid thermal damage.
Mounting:
- Mount the device on a PCB with proper heat dissipation considerations, especially when sensing high currents.
- Ensure that the primary conductor is aligned correctly with the center pin to achieve accurate current measurements.
Testing and Calibration:
- After installation, test the device by applying known currents and measuring the output voltage to verify the accuracy of the sensor.
- If necessary, calibrate the output using a known reference current and adjust the sensitivity accordingly.
By following these instructions, you can ensure reliable and accurate current sensing with the ACS722LLCTR-40AB-T.
(For reference only)View more about ACS722LLCTR-40AB-T on main site